PRASTEL TCO7RX Manual Download Page 4

FRA   ENG 

 ITA 

 ESP   DEU   POR 

 

                        4 / 6 

5.2 Learning of the transmitter on the second relay of the receiver 

3

 

4

 

6

 

Release the key of the transmitter

 

Press and keep pressed 

the key present on 

the receiver.   

DO NOT 

release the key on the receiver.  

The receiver emits 

bips.

 

The learning ended correctly.

 

 

1

 

Check  that  the  DIP  3  and  4  of  the 
transmitter and of the receiver are set in the 
same way. 

Press and keep pressed 

the key present on 

the transmitter. 

The receiver emits 

bips.

 

5

 

Release

 the key on the receiver. 

NOTE: in case in which instead 4 BIP are reproduced, it means that the maximum number of transmitters for the selected channel has been 
reached and that no new devices on the same relay can be memorized. 
In case in which a device previously memorized is then associated to the other relay, it will be automatically removed from the previous relay. 
For example, if a device memorized on the relay 1 is memorized on the relay 2 it will be automatically removed from the relay 1. 

Acoustic signalling during the learning phase 

Number of BIP 

Meaning  

Transmitter correctly memorized 

Mistake : the  maximum number of transmitter for selected channel has been reached 

Maximum time up for the memorization of the transmitter (10 second) 

5.3  Summary of the acoustic signalling during the learning phase 

Beside the two receiver relays a jumper for the selection of the type signal to give on output is present. This signal can be:  
1.

 

A clean contact : open contact in case of alarm and close if the alarm is not present 

2.

 

A contact type 8,2K : resistance of the contact = 0 or ∞ (Open loop) Ohm in case of alarm and 8,2K

Ω

 if the alarm is not present. The control 

unit connected to the device must be able to handle this type of signal. 

The selection of the type of signal is carried out in the following way: 

Jumper Pos. 1 

Jumper Pos. 2 

Position 1 : clean contact functioning (Mec) 
Position 2 : 8K2 functioning (8,2K) 

6.  SELECTION OF THE TYPE OF SIGNAL ON OUTPUT RELAY 

2

 

MEC. 

8K2 

2

 

3

 

4

 

Press and keep pressed 

the key present on 

the receiver.   

Release

 the key on the receiver. 

1

 

5.  LEARNING 

5.1 Learning of the transmitters on the first relay of the receiver 

Check that the DIP 3 and 4 of the transmitter 
and of the receiver are set in the same way. 

Press and keep pressed 

the key present on 

the transmitter. 

Release the key of the transmitter

 

5

 

The receiver emits 

1

  bip

 

 

The receiver emits 

1

 bip

 

 

The receiver emits 

bips.

 

The learning ended correctly.

 

For the successive learning, repeat the operation from point 1. 

Summary of Contents for TCO7RX

Page 1: ...ive edges TRANSMITTER TCO7TX TCO7RX TCO7TX Notified Body Directive 98 37 EC EC ident N 1844 PRASTEL FRANCE ZI Athélia II 225 Impasse du Serpolet 13704 LA CIOTAT Cedex FRANCE Tel 334 42 98 06 06 Fax 334 42 04 53 51 RECEIVER TCO7RX Bidirectional communication ...

Page 2: ...flat Transceiver system 1 DESCRIPTION 2 CONFIGURATION AND ELECTRICAL CONNECTIONS NOTE The signal given on output clean contact or 8 2K to the relay 1 and 2 depends on the position of the selection output signal jumper 2 1 Receiver TCO7RX Jumper of selection power supply tension Right 12Vac dc Left 24Vac dc Dip switch Programming reset key WARNING if the power supply of the TCO7RX is carried out in...

Page 3: ...ip 3 and dip 4 which will have to correspond to the one of the transmitters 5 The inputs are handled in the same way as the photocells test the control unit to carry out the photocells test switches off the power supply of the receiver and check that the relays of the correspondent receiver opens itself In this device the input TEST1 and TEST2 are for testing the security devices see chapter 12 MI...

Page 4: ...annel has been reached 1 Maximum time up for the memorization of the transmitter 10 second 5 3 Summary of the acoustic signalling during the learning phase Beside the two receiver relays a jumper for the selection of the type signal to give on output is present This signal can be 1 A clean contact open contact in case of alarm and close if the alarm is not present 2 A contact type 8 2K resistance ...

Page 5: ...r emits one uninterrupted bip N B If one transmitter is in alarm but it necessary to open or close the automation in any case it s necessary to press and keep pressed the programming test button of the indicted transmitter of the indicated and in the same time to move the automation WARNING If the batteries are completely flat it will be necessary to change them The battery life is of about 2 year...

Page 6: ...e it will be necessary to keep in consideration the condition of dangerous that can be created if the power supply battery is taken off to the transmitter during the interval of time before the successive transmission of its state and successively the sensible edge goes on alarm in this case the receiver will signal the alarm only after the period of interrogation With the dip 2 of the transmitter...

Reviews: