Fix the device as much higher than possible in such way as there are
no obstacles on the direction of the receiver and in such a way as the
maximum distance between the two devices is less than 30 meters.
Set the dip switch relative to the utilized frequency (dip 3 and dip 4)
which will have to correspond to the one of the receiver.
4. CONNECTIONS
4.1 Transmitter connection
1
Connect the safety edge to the terminals of the transmitter. Direct
and place the device as shown on the figure.
Give power to the system connecting the two batteries AA – 1,5 V to
the battery holder.
Pay attention to the polarity .
2
3
4
Connect the test inputs to the control unit, in case they are utilized (*).
Set the 2 little bridges Mec/8K2 (Jumper of selection output signal ) in
such a way as the state of functioning or of alarm is correctly
signaled, according to whether the control unit has an input of
mechanical type (with contact) or 8,2K
Ω
.
1
4.2 Receiver connection
Put the receiver in such a way to minimize the distance from the
transmitters associated and close the to the automation’s control unit
or inside the box of the motor. If fixed to a wall, utilize suitable screws
and plugs so that it can resist to a force of 50N downwards.
Set the little bridge of power supply (24V o 12V)
Set the dip switch relative to the utilized frequency (dip 3 and dip 4)
which will have to correspond to the one of the transmitters.
5
(*) The inputs are handled in the same way as the photocells test: the control unit, to carry out the photocells test, switches off the power supply of the
receiver and check that the relays of the correspondent receiver opens itself. In this device, the input TEST1 and TEST2 are for testing the security
devices (see chapter 12).
MIN: 20 cm
WARNING : The manufacturer can not be considered
responsible for any damages caused by an improper,
incorrect or irrational use of the product.
WARNING: keep free the areas of access to the devices
and clean periodically them from eventual dirtiness
which can settle on them during the normal functioning.
It is possible to associate up to a maximum of 4 transmitters (4 different edges) to each relay. For this reason, to each receiver can be associated a
maximum of 8 transmitters.
Warning: for a correct functioning of the system, every transmitter part must have the frequency dip put on the same way as the
correspondent receiver part.
In order to avoid any interferences on installations which need a higher number than 4 security channels it is advisable to distinguish the frequencies
utilized among the various receivers and their transmitters associated transmitters.
N° DIP
Function
1
Mechanical or resistive
safety edge.
2
Energy saving
3
Selection frequency of
functioning
4
N° DIP
Function
1
Test device
2
Buzzer ON / OFF
3
Selection frequency of
functioning
4
TRANSMITTER TCO7TX
RECEIVER TCO7RX
3. SETTINGS
DIP
ON
OFF
DIP
ON
OFF
1 2 3 4
1 2 3 4