MR1ESLIM
ENGLISH
ISMR1ESLIM_12_07.DOC
1. GENERAL
INFORMATION
The receiver integrates the functions of receiver and decoder of the signals coming from the FSLIMRF infra red barriers. It’s memory is capable
of memorising up to 200 different codes generated by the FSLIMRF barriers.
2. MAIN
TECHNICAL
FEATURES
Power supply
12 - 24 VAC/DC
Average Work/Rest consumption
40 mA / 22 mA
Reception frequency
433.920 MHz
Number barriers memorisable
200
Number of channels
1
Types of output
Monostable, bistable
Output Relay
Contact capacity
0.5 A @ 24 VAC/DC
Signals Red
led
Working temperature
-20/+55 °C
Storage temperature
-40/+85 °C
Size / Weight
100 x 55 x 22 mm 70g
3.
SELECTION OF SUPPLY VOLTAGE
The receiver can be supplied at 24 VAC/DC through terminals 1 and 2 (Fig. 1) and at 12 VAC/DC through terminals 2 and 3 (Fig. 1).
4.
CODE PROGRAMMING AND CANCELLATION
Operations of inserting a new code into the memory and cancelling the whole list of codes can be carried out using the same button P1 on the
receiver.
Programming
•
Power up the receiver correctly.
•
Press button P1: the red led lights up indicating that programming is in progress.
•
Make a transmission by pressing the ALIGN/RADIO button on the barrier.
•
The code is inserted into the memory. The led flashes during insertion. At the end, the led returns to the non-flashing state, indicating that
a new code may be inserted.
•
Memorise all the barriers by making a transmission with each one of them.
•
At the end of the operation press button P1 again to exit from the procedure. The led goes out. Exit from the programme comes about
automatically in any case 10 seconds after the last memorisation.
•
The codes remain in the memory even if the power supply is cut.
ATTENTION
: In order to receive the TAMPER and/or FLAT BATTERY signals from the SLAVE barrier, this too must be fitted with the FSLIMTX
radio module which must be memorised on the receiver.
Total cancellation of codes
•
Hold button P1 pressed until the red led starts flashing.
•
Press button P1 again within 6 seconds to confirm cancellation. Confirmation is indicated by the led flashing with greater frequency.
5. CHANNEL
SELECTION
Jumper JP3 (see fig. 1) selects which type of signal, coming from the FSLIMRF barrier, activates the output relay.
POSITION 1: INTRUSION
POSITION 2: TAMPER
POSITION 3: FLAT BATTERY
POSITION 4: NOT USED
6.
SELECTION OF RELAY OPERATING MODE
Jumper JP2 (see fig. 1) selects the relay operating mode:
JP2 CLOSED: MONOSTABLE
JP2 OPEN: BISTABLE
In bistable mode, if the jumper JP3 is in position 1 (INTRUSION) or 2 (TAMPER), the relay activates on receiving the INTRUSION or TAMPER
signals and deactivates when all the barriers have sent the anomaly end signal. If the jumper is in position 3 (FLAT BATTERY), the relay
operation is always monostable, independently from the position of JP2.
DECLARATION OF CONFORMITY
Prastel S.p.A. declares that the following equipment
RECEIVER MR1ESLIM
IS IN ACCORDANCE with the 99/05/EC (R&TTE) direcitve
The complete declaration of conformity is available in Prastel.