prana 150 ERP LITE Technical-Operating Documentation Download Page 6

6

Bidirectional  ventilation  unit  with  heat  recovery  “PRANA”  is  a  monoblock  ready  for  use  in 

accordance with design and assembly tasks and conditions.

The system is mounted in a hole of the appropriate diameter in the upper part of the wall 

adjoining the outside, at a distance of no less than 100-150 mm from the ceiling or walls. The 

through hole should be a slope of 3-5 degrees towards the outside. The operating module of 

the ventilation unit is mounted in the hole using a seal (Fig. 4).

The length of the working module should correspond to the thickness of the wall in which 

the installation will be carried out. In order to ensure the normal operation of the system, it 

is necessary that its body facing the the outside extends beyond the wall by 1-2 cm to the 

beginning of the air intake (Fig. 4).

INSTALATION

Fig. 4. The diagram of installing the recuperator in the wall.

air intake

sealant

100-150 mm

from the ceiling

Fig. 5. An example of mounting of the recuperator “PRANA-150”, “PRANA-200G”, “PRANA-200C”.

Other preparatory works:

- preparation of the hole for installing the switch and preparation of the grooves for the 

installation of the electrical supply network between the system, the switch and the place of 

connection of the system to the power supply source.

Summary of Contents for 150 ERP LITE

Page 1: ...1 8 TECHNICAL OPERATING DOCUMENTATION Bidirectional unit with heat recovery PRANA 150 ERP LITE PRANA 200C ERP LITE PRANA 200G ERP LITE ...

Page 2: ...E DEVICE Ventilation units PRANA 150 PRANA 200C PRANA 200G are intended for creation and maintenance of healthy microclimate in premises These systems are recommended for use in residential and public facilities apartments houses office premises educational establishments kindergartens etc PRANA 150 and PRANA 200 belong to the category of innovative and reliable products aimed at creating and maint...

Page 3: ... Mode is mandatory TECHNICAL DATA PRANA 150 PRANA 200G PRANA 200C Diameter of the working module mm with thermal insulation mm 150 160 200 210 200 210 Diameter of the mounting hole mm Length of the working module mm 162 475 215 440 215 500 Recommended area of the premises m 2 60 60 120 Amounts of air exchange during recovery m3 h the inflow and exhaust work simultaneously inflow exhaust night minima...

Page 4: ... and switched off motors It lies in the movement of uncontrolled airfl ows through the recuperator due to the difference in pressure and temperature inside and outside the premises It is allowed to use when the difference between outside and inside temperatures is no more than 5 o C Defrosting WARNING In the cold season the improper operation of the recuperator is likely to freeze it When freezing ...

Page 5: ... and the dimensions of ventilation units PRANA 150 PRANA 200G PRANA 200C a the ventilation grid and air intake in the premises b monoblock side view c the ventilation grid and air intake from the outside 535 475 35mm 500mm 475 a a a a b b b b c c c c ...

Page 6: ...nstallation will be carried out In order to ensure the normal operation of the system it is necessary that its body facing the the outside extends beyond the wall by 1 2 cm to the beginning of the air intake Fig 4 INSTALATION Fig 4 The diagram of installing the recuperator in the wall air intake sealant airborne airborne grid grid sealan 50 mm 50 mm unit slope unit slope 3 5 degrees 3 5 degrees se...

Page 7: ...ator Shorten the electric cable from the recuperator to a length that is convenient for electrical connection All electrical cables used in the installation should have the cross section of 0 5 0 75 mm The operation of the system is controlled using a remote control or mobile application that controls the operation of the fans installed in the body of the ventilation system it turns on regulates a...

Page 8: ...he graphic symbols of the indication correct operation of the device in accordance with the control devices The device must be turned off in case of excessive oscillations and noise damage to the elements of the device body damage to the insulation of the electric cable damage to the elements of automation the temperature of the outside air is below 30 ºС 1 The lid is closed Do not tunr on the dev...

Page 9: ...screws through special openings Remove the flange 6 Turn the mounting locks of the front cover MAINTENANCE The maintenance consists in periodic recommended 1 2 times a year and preventive inspection of surfaces of the fans and the heat exchanger and if necessary in cleaning them The procedure for disassembling assembling the device for after cleaning 10 Remove the blades from the fan housings and c...

Page 10: ...temperature from 20 С to 40 С TRANSPORTATION AND STORAGE RULES 12 The drain in the heat exchanger and the body must coincide and be below during the installation 13 The heating of the condensate drainage the heating element must be located beneath near the hole in the housing 14 The flange must be installed correctly the larger protrusion of the should be below 11 Clean the heat exchanger in adry o...

Page 11: ...ed out only after the device is disconnected from the electrical supply network WARNING Do not operate the ventilation unit if there is a threat that foreign objects may enter the inflow part of the body which objects may jam or damage the impeller of any of the two fans WARNING Do not operate the ventilation unit in premises where the air contains aggressive substances and does not correspond to t...

Page 12: ...12 ...