prana 150 ERP LITE Technical-Operating Documentation Download Page 10

10

ASSEMBLY IN THE REVERSE ORDER

The  technological  process  provides  for  100%  inbound  quality  control  for  all  components, 

as  well  as  double  100%  inbound  control  after  their  manufacture  and  24-hour  run  in  the 

maximum power mode.

Transportation and storage of the products in individual packing boxes is ensured in a 

horizontal position.
Keep the recuperator in the factory packaging under the cover or (in enclosed space) with 

relative humidity of air of no more than 70% and air temperature from -20˚С to + 40˚С.

TRANSPORTATION AND STORAGE RULES

12. The drain in the 

heat exchanger and 

the body

must coincide and 

be below during the 

installation.

13. The heating of the condensate drainage 

(the heating element) must be located 

beneath near the hole in the housing. 

14. The fl ange must be installed 

correctly; the larger protrusion of 

the should be below.

>

11. Clean the heat exchanger in adry or, if 

necessary, in a wet manner.

WARNING!
Before rinsing or wet cleaning of the 

heat exchanger, make sure that all 

the electrical components and parts 

are removed from the heat exchanger 

(except for the components of 

“Mini heating up” and “heating the 

condensate drainage”.

QUALITY

Summary of Contents for 150 ERP LITE

Page 1: ...1 8 TECHNICAL OPERATING DOCUMENTATION Bidirectional unit with heat recovery PRANA 150 ERP LITE PRANA 200C ERP LITE PRANA 200G ERP LITE ...

Page 2: ...E DEVICE Ventilation units PRANA 150 PRANA 200C PRANA 200G are intended for creation and maintenance of healthy microclimate in premises These systems are recommended for use in residential and public facilities apartments houses office premises educational establishments kindergartens etc PRANA 150 and PRANA 200 belong to the category of innovative and reliable products aimed at creating and maint...

Page 3: ... Mode is mandatory TECHNICAL DATA PRANA 150 PRANA 200G PRANA 200C Diameter of the working module mm with thermal insulation mm 150 160 200 210 200 210 Diameter of the mounting hole mm Length of the working module mm 162 475 215 440 215 500 Recommended area of the premises m 2 60 60 120 Amounts of air exchange during recovery m3 h the inflow and exhaust work simultaneously inflow exhaust night minima...

Page 4: ... and switched off motors It lies in the movement of uncontrolled airfl ows through the recuperator due to the difference in pressure and temperature inside and outside the premises It is allowed to use when the difference between outside and inside temperatures is no more than 5 o C Defrosting WARNING In the cold season the improper operation of the recuperator is likely to freeze it When freezing ...

Page 5: ... and the dimensions of ventilation units PRANA 150 PRANA 200G PRANA 200C a the ventilation grid and air intake in the premises b monoblock side view c the ventilation grid and air intake from the outside 535 475 35mm 500mm 475 a a a a b b b b c c c c ...

Page 6: ...nstallation will be carried out In order to ensure the normal operation of the system it is necessary that its body facing the the outside extends beyond the wall by 1 2 cm to the beginning of the air intake Fig 4 INSTALATION Fig 4 The diagram of installing the recuperator in the wall air intake sealant airborne airborne grid grid sealan 50 mm 50 mm unit slope unit slope 3 5 degrees 3 5 degrees se...

Page 7: ...ator Shorten the electric cable from the recuperator to a length that is convenient for electrical connection All electrical cables used in the installation should have the cross section of 0 5 0 75 mm The operation of the system is controlled using a remote control or mobile application that controls the operation of the fans installed in the body of the ventilation system it turns on regulates a...

Page 8: ...he graphic symbols of the indication correct operation of the device in accordance with the control devices The device must be turned off in case of excessive oscillations and noise damage to the elements of the device body damage to the insulation of the electric cable damage to the elements of automation the temperature of the outside air is below 30 ºС 1 The lid is closed Do not tunr on the dev...

Page 9: ...screws through special openings Remove the flange 6 Turn the mounting locks of the front cover MAINTENANCE The maintenance consists in periodic recommended 1 2 times a year and preventive inspection of surfaces of the fans and the heat exchanger and if necessary in cleaning them The procedure for disassembling assembling the device for after cleaning 10 Remove the blades from the fan housings and c...

Page 10: ...temperature from 20 С to 40 С TRANSPORTATION AND STORAGE RULES 12 The drain in the heat exchanger and the body must coincide and be below during the installation 13 The heating of the condensate drainage the heating element must be located beneath near the hole in the housing 14 The flange must be installed correctly the larger protrusion of the should be below 11 Clean the heat exchanger in adry o...

Page 11: ...ed out only after the device is disconnected from the electrical supply network WARNING Do not operate the ventilation unit if there is a threat that foreign objects may enter the inflow part of the body which objects may jam or damage the impeller of any of the two fans WARNING Do not operate the ventilation unit in premises where the air contains aggressive substances and does not correspond to t...

Page 12: ...12 ...

Reviews: