ENGLISH 17
RISK
The
module
must
be
installed
taking
into
account
its
thermal
features.
In
order
to
guarantee
air
flow
around
the
module,
sufficient
room
must
be
provided
between
the
panel
and
the
mounting
system.
This
room
will
allow
heat
dissipation
and
will
limit
the
creation
of
condensation
and
humidity.
Furthermore,
to
avoid
mechanical
failures,
modules
must
be
spaced
to
allow
thermal
expansion.
RISK
The
structure
on
which
the
modules
(or
a
single
module)
shall
be
mounted
must
have
resting
points
that
are
perfectly
coplanar
between
themselves.
When
tightening
clamps
or
bolts
for
assembly,
absolutely
avoid
applying
a
torque
that
may
risk
breaking
the
module
(see
point
5
of
mounting
procedure).
RISK
Partial
shading
on
modules
must
be
absolutely
avoided,
in
particular
a
shading
area
which
is
parallel
to
the
cells
may
lead
to
an
irreversible
damage
of
the
module.