5/22
POWER SUPPLY-MAINS
Connect the power cord as follows:
L (live) =brown
E (earth) =yellow/green
N (neutral) =blue
Before connection with mains power, make sure that the voltage and frequency marked on the rating plate of the projector match what
are supplied. It is recommended that each projector be supplied separately so that they may be individually switched on and off.
IMPORTANT
It is essential that each projector is correctly earthed(yellow/green twin wire) and the electrical installation conforms to all
relevant standards.
CONTROL CONNECTION
Connection between controller and projector and between one projector and another must be made with a twin-screened cable, with
each wire having at least a 0.5mm in diameter. Connection to and from the projector is via cannon 5 pin (which are included with the
projector) or 5 pin XLR plugs and sockets. The XLR's are connected as shown in the figure above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. XLR plugs and sockets
mustn’t be connected in any way other than mentioned in the above figure. The XR 1000 Framing accepts digital control signals in
protocol DMX512 (1990).
Connect the controller’s DMX output to the first fixture’s DMX input, and connect the first fixture’s DMX output to the second
fixture’s DMX input and connect the rest fixtures in the same way. Eventually connect the last fixture’s DMX output to a DMX
terminator as shown in the figure below.
DMX IN
DMX OUT
TO
DMX TERMINATOR
TO
DMX CONTROLLER
DMX IN
DMX OUT
DMX IN
DMX OUT