15
8.
ERROR MESSAGE
Name
Type
Correction
Pan
Optical sensor error: Pan
Check if wiring, optical sensor and motors are normal
Tilt
Optical sensor error: Tilt
Check if wiring, optical sensor and motors are normal
Pan & Tilt driver board
Communication error: module1 Check if wiring, hall sensor and motors are normal
Motor driver board
Communication error: module2 Check if wiring, hall sensor and motors are normal
Focus
Hall error: Focus
Check if wiring, hall sensor and motors are normal
Color wheel
Hall error: Color wheel
Check if wiring, hall sensor and motors are normal
Fixed gobo wheel
Hall error: Fixed gobo wheel
Check if wiring, hall sensor and motors are normal
Lamp striking
Lamp striking error
Check if wiring and igniter are normal and if the voltage of
the igniter is normal
9.
TECHNICAL DATA
ELECTRIC PARAMETERS
Input voltage
200V~240V AC
,
50/60Hz
Input power 600W@230V
Power factor PF>0.90
THE SPECIFICATIONS OF THE LIGHT SOURCE
Lamp MSD Platinum 300S Flex
Color temperature
7800K
rated life 6000hrs
64-255
Prism 2 in
10
12
Prism rotation
0-127
0-360°
128-190
Clockwise rotation: Fast->Slow
191-192
Stop
192-255
Anti-clockwise rotation: slow->fast
11
13
Frost
0-255
0-100%
12
14
Focus
0-255
0-100%
13
15
Reset
0-25
NO
26-76
Head reset
77-127
Pan & Tilt reset
128-255
Total reset
14
16
Lamp control
0-25
No
26-100
Lamp off
101-255
Lamp on