INSTALL THE PROJECTOR
HANDLE
SAFETY CORDS
CLAMP
4PCS
2PCS
2PCS
CLIP
4PCS
WATERPROOF
1PC
CONNECTOR
Fitted on the floor
Fitted on the celling
PLUG WITH
POWER BOX
HOLE FOR
2PCS
DMX
HOLE FOR
CONNECTOR
HOLE FOR
The unit was designed to make installation easy: it can be fitted on a floor, wall or ceiling as required and will
operate in any working position,
Take fastfit clamps and 4 safety cords out from the package and mount them on the underside of fixture. Hang the fixture
on the structure and fasten the screws attached to each clamp. Always ensure that the projector is firmly anchored to
avoid vibration and slipping whilst functioning. Always ensure that the structure that you are going to mount the projector
is secure and is strong enough to support a weight of MEGA COLOUR 2500.
WARNING:
1. Unlock the PAN and TILT before the 1
st
application of projector for safety.
2. The projector MUST be lifted or carried by the HANDLES instead of clamps.
3. For safety the safety cord should afford 10 times of the unit’s weight.
FITTING THE LAMP
Lock the yoke before fitting/replacing the lamp.
Loosen 4 clips and open the front covers.
Remove and rotate the filter module by undoing 2 M4 screws, then you will see the lamp holder and reflector.
Do not change new lamp until old lamp has cooled.
Insert the new lamp in the lamp-holder, and ensure the little bubble on the lamp is at a right angle (90°) to the beam path.
Keep the lamp clean during installation.
Fasten 2 M3 screws at the both ends of lamp.
Put back the filter module and fasten 2 M4 screws.
Close the front cover and fasten 4 clips.