6/18
DMX TERMINATOR
In the Controller mode, at the last fixture in the chain, the DMX output has to be connected with a DMX terminator. This
prevents electrical noise from disturbing and corrupting the DMX control signals.
The DMX terminator is simply an XLR connector with a 120
Ω
(ohm) resistor connected across pins 2 and 3, which is
then plugged into the output socket on the last projector in the chain. The connections are illustrated below.
2
1
3
120
DMX TERMINATOR
CONNECTION
Connect a 120 (OHM) resistor
across pins 2 and 3 in an XLR plug
and insert into the DMX out socket
on the last unit in the chain.
PIN 3
PIN 2
SETUP OPTIONS-PROJECTOR CONFIGURATION
UP
Projector configuration can be set conveniently via pressbutton switch and LED display. Turn the projector on and the
LED display will show DMX address you set and save last time and it can be reset and saved again as you please.
Launch the projector. Press button ENTER more than 5 seconds to unlock panel.
Press button UP or DOWN if you want to browse through the various Setup Options.
Press button ENTER to save your settings or enter the next menu.
Press button UP or DOWN to shift.
Press button FUNC, it will return to the upper menu one by one. If you do not, the system will display DMX start address
after 60 seconds automatically.
TO SET THE DMX START ADDRESS
Each MEGA COLOUR 2000 must be given a DMX start address so that the correct projector responds to the correct
control signals. This DMX start address is the channel number from which the projector starts to “listen” to the digital
control information being sent out from the controller. The MEGA COLOUR 2000 has 2 DMX modes. There are
standard mode and short mode. For example standard mode has 13 channels, so set the No. 1 projector’s address 001,
No. 2 projector’s address 014, No. 3 projector’s address 027, No. 4 projector’s address 040, and so on.
Launch the projector. Press button ENTER more than 5 seconds to unlock panel.
Press button FUNC to display
DMX address
;
Press button UP and DOWN, you can set the address;
Press button ENTER to confirm.
The DMX start address can be set discretionarily under the STAND-ALONE control mode. It is recommended that the
DMX start address must be set correctly so that the unit may be individually switched on and off when multi-projectors
controlled by controller.