Cautions:

 For added protection mount the fixtures in areas outside walking paths, 

seating areas, or in areas were the fixture might be reached by unauthorized personnel.

Before mounting the fixture to any surface, make sure that the installation area can 

hold a minimum point load of 10 times the device’s weight.

Fixture installation must always be secured with a secondar y safety attachment, such 

as an appropriate safety cable.

Never stand directly below the device when mounting, removing, or servicing the fixture.  

· 

 

The JNR PAR ZOOM 3618 is for wash effect for on-site decoration purpose.

· 

 

Don’t turn on the fixture if it’s been through severe temperature difference like 

after transportation because it might damage the light due to the environment 

changes. So make sure to operate the fixture until it is in normal temperature.

· 

 

This light should be keep away from strong shaking during any transportation or 

movement.

· 

 

Don’t pull up the light by only the head, or it might cause damages to the 

mechanical parts.

· 

 

Don’t expose the fixture in overheat, moisture or environment with too much dust 

when installing it.  And don’t lay any power cables on the floor. Or it might cause 

electronic shock to the people. 

· 

 

Make sure the installation place is in good safety condition before installing the 

fixture.

· 

 

Make sure to put the safety chain and check whether the screws are screwed 

properly when installing the fixture.

· 

 

Make sure the lens are in good condition. It’s recommended to replace the units if 

there are any damages or severe scratch.

· 

 

Make sure the fixture is operated by qualified personnel who knows the fixture 

before using.

· 

 

Keep the original packages if any second shipment is needed.

· 

 

Don’t tr y to change the fixtures without any instruction by the manufacturer or 

the appointed repairing agencies. 

· 

 

It is not in warranty range if there are any malfunctions from not following the 

user manual to operate or any illegal operation, like shock short circuit, electronic 

shock , lamp broke, etc.

OPERATION INSTRUCTIONS

4

INSTALLATIONS

5

.06.

6

Truss

 

installing

Satety

 

Clamp

Safety

 

Cable

from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture 

is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).

Always use and install the supplied safety cable as a safety measure to prevent 

accidental damage and/or injur y in the event the clamp fails.

Mounting points:

 Overhead mounting requires extensive experience, including 

amongst others calculating working load limits, a fine knowledge of the installation 

material being used, and periodic safety inspection of all installation material and the 

fixture. If you lack these qualifications, do not attempt the installation yourself. 

Improper installation can result in bodily injur y.

Be sure to complete all rigging and installation procedures before connecting the 

main power cord to the appropriate wall outlet.

Clamp mounting: 

The JNR PAR ZOOM 3618 provides a unique mounting bracket 

assembly, and the safety cable rigging point in one unit (see the illustration below). 

When mounting this fixture to truss be sure to secure an appropriately rated clamp to 

the handle using a M10 screw fitted through the center hole of the handle. As an 

added safety measure be sure to attached at least one properly rated safety cable to 

the fixture using on of the safety cable rigging point.

Floor

 

projection

Summary of Contents for JUNIOR JNR PAR ZOOM 3618

Page 1: ...JNR PAR ZOOM 3618 JNR 8134C PR LIGHTING LTD http www pr lighting com 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 ...

Page 2: ... instructions and warning notes written in this user manual CAUTION Becareful with your operations With a dangerous voltage you cansuffer a dangerous electric shock when touching wires IMPORTANT Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems SAFETY INSTRUCTIONS 1 10 The following points have...

Page 3: ...nsportation And please check whether the following items are included inside the box 02 UNPACKING 2 09 DMX CHANNELS 8 0 100 Red dimmer 0 100 Green dimmer 0 100 Blue dimmer 0 100 White dimmer 0 100 Amber dimmer Zoom from 10 to 60 0 100 UV dimmer Description Channel Function Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Red Green Blue White Amber UV Zoom 1 2 3 4 5 6 7 7CH Mode 11CH Mode 0 100 Line...

Page 4: ...4 units at 120V and 8 units at 230V 08 DMX Output 3 Pin XLR Socket DMX Input 3 Pin XLR Socket 1 Ground 2 Data 3 Data 1 2 3 1 2 3 1 2 3 1 2 3 COMMON DMX DMX DMX512 IN 3 PIN XLR DMX512 OUT 3 PIN XLR 2 1 For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing...

Page 5: ...ng The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator DMX 512 CONTROL CONNECTIONS 6 300 295 400 POWER IN DMX IN FUNC UP LED DISPLAY DOWN ENTER GROUND POWER IN DMX IN DMX OUT 8 60 Beam Angle LUX 0 0929 FC Photometric Beam Angle Data 75 804 222 2394 60 650 18 1932 344 3704 5 54 677 7284 FC L...

Page 6: ... who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc OPERA...

Reviews: