.04.
.07.
Regardless of the rigging option you choose for your
, always be
sure to secure your fixture with a safety cable. The fixture provides a built-in rigging
point for a safety cable on the hanging bracket as illustrated above. Be sure to only
use the designated rigging point for the safety cable and never secure a safety cable
to a carr ying handle.
JNR PAR ZOOM 3618
Connect the provided XLR cable to the female 3-pin XLR output of your controller and
the other side to the male 3-pin XLR input of the par can. You can chain multiple
Par can together through serial linking. The cable needed should be two core,
screened cable with XLR input and output connectors. Please refer to the diagram
below.
DMX-512 connection with DMX terminator
DMX-512 CONTROL CONNECTIONS
6
300
29
5
400
POWER IN
DMX IN
FUNC
UP
LED DISPLAY
DOWN
ENTER
GROUND
POWER IN
DMX IN
DMX OUT
8
°~
60
°
Beam Angle LUX 0.0929=FC
×
Photometric Beam Angle Data
75/804
222/2394
60/650
18/1932
344/3704
5/54
677/7284
(FC/LUX)
R
G
B
A
W
UV
RGBAW+UV
8
°
60
°
1m (3.3ft) 3m (9.8ft) 5m (16.4ft)
0m (0ft)
7m (23.0ft)
PHOTOMETRIC DATA
4
197/2125
602/6486
398/1758
76/814
1903/20483
2/25
1903/20483
6/70
6/70
8/82
6/68
42/456
-/-
83/896
19/201
66/706
21/222
16/172
214/2305
-/-
214/2304
2/26
2/26
3/29
2/26
15/161
-/-
30/322
7/81
28/303
8/84
7/73
87/938
-/-
87/938
1/15
1/15
1/14
1/14
8/85
-/-
16/173
3/37
14/152
5/58
3/38
43/469
-/-
43/469