.01.

If the device has been exposed to temperature changes due to environmental changes, 

do not switch it on immediately. The arising condensation could damage the device. 

Leave the device switched off until it has reached room temperature.

This device falls under protection-class I. Therefore it is essential that the device be 

earthed.

The electric connection must carr y out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this manual.

Make sure the power cord is never crimped or damaged by sharp edges. If this would 

be the case, replacement of the cable must be done by an authorized dealer.

Always disconnect from the mains, when the device is not in use or before cleaning it. 

Only handle the power cord by the plug. Never pull out the plug by tugging the power 

cord.

During initial start-up some smoke or smell may arise. This is a normal process and 

does not necessarily mean that the device is defective, it should decrease gradually.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm 

distance with wall for smooth air flow, so there should be no shelter for fans and 

ventilation for heat radiation.

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively 

replaced by the manufacturer or his ser vice agent or a similar qualified person in order 

to avoid a hazard.

This device has left the factor y in perfect condition. In order to maintain this 

condition and to ensure a safe operation, it is absolutely necessar y for the user to 

follow the safety instructions and warning notes written in this user manual.

CAU T I O N

Becareful with your operations.With a dangerous voltage you cansuffer a 
dangerous electric shock when touching wires!

IMPORTANT

Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.

SAFETY INSTRUCTIONS

1

.10.

The following points have to be considered during the inspection:

1)  All screws for installing the devices or parts of the device have to be tightly 

connected and must not be corroded.

2)  There must not be any deformations on the housing, color lenses, fixations and 

installation spots (ceiling, suspension, trussing).

3)  Mechanically moved parts must not show any traces of wearing and must not 

rotate with unbalances.

4)  The electric power supply cables must not show any damage, material fatigue or 

sediments. 

Further instructions depending on the installation spot and usage have to be 

adhered by a skilled installer and any safety problems have to be removed.

In order to make the lights in good condition and extend the life time, we suggest a 

regular cleaning to the lights.

1)  Clean the inside and outside lens each week to avoid the weakneness of the lights 

due to accumulation of dust.

2)  Clean the fan each week .

3)  A detailed electric check by approved electrical engineer each three month, make 

sure that the circuit contacts are in good condition,  prevent the poor contact of 

circuit from overheating. 

We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. 

Never use alcohol or solvents.

There are no ser viceable parts inside the device. Please refer to the instructions 

under “Installation instructions”.

Should you need any spare parts, please order genuine parts from your local dealer.

MAINTENANCE AND CLEANING

9

Disconnect from mains before starting maintenance operation.

CAU T I O N

Summary of Contents for JUNIOR JNR PAR ZOOM 3618

Page 1: ...JNR PAR ZOOM 3618 JNR 8134C PR LIGHTING LTD http www pr lighting com 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 ...

Page 2: ... instructions and warning notes written in this user manual CAUTION Becareful with your operations With a dangerous voltage you cansuffer a dangerous electric shock when touching wires IMPORTANT Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems SAFETY INSTRUCTIONS 1 10 The following points have...

Page 3: ...nsportation And please check whether the following items are included inside the box 02 UNPACKING 2 09 DMX CHANNELS 8 0 100 Red dimmer 0 100 Green dimmer 0 100 Blue dimmer 0 100 White dimmer 0 100 Amber dimmer Zoom from 10 to 60 0 100 UV dimmer Description Channel Function Value 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Red Green Blue White Amber UV Zoom 1 2 3 4 5 6 7 7CH Mode 11CH Mode 0 100 Line...

Page 4: ...4 units at 120V and 8 units at 230V 08 DMX Output 3 Pin XLR Socket DMX Input 3 Pin XLR Socket 1 Ground 2 Data 3 Data 1 2 3 1 2 3 1 2 3 1 2 3 COMMON DMX DMX DMX512 IN 3 PIN XLR DMX512 OUT 3 PIN XLR 2 1 For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing...

Page 5: ...ng The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator DMX 512 CONTROL CONNECTIONS 6 300 295 400 POWER IN DMX IN FUNC UP LED DISPLAY DOWN ENTER GROUND POWER IN DMX IN DMX OUT 8 60 Beam Angle LUX 0 0929 FC Photometric Beam Angle Data 75 804 222 2394 60 650 18 1932 344 3704 5 54 677 7284 FC L...

Page 6: ... who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like shock short circuit electronic shock lamp broke etc OPERA...

Reviews: