![PR Lighting AQUA 350 BEAM PR-2368 Manual Download Page 8](http://html1.mh-extra.com/html/pr-lighting/aqua-350-beam-pr-2368/aqua-350-beam-pr-2368_manual_1593127008.webp)
8/26
●
INSTALLATION/REPLACEMENT OF A LAMP
Lock the yoke before fitting/replacing the lamp.
Just as Shown by Figure 1, after Opening the airflow cover as shown by loosening 4 tightening screws, the structure like figure 2 will
be seen.
Just as shown by the figure 2, loosen the 4 tightening screws of the bob-weight block, take it down and the structure like figure 3 will
be seen.
Just as shown by figure 3, loosen the 8 tightening screws of lamp cover , open the cover and structure like the figure 4 will be seen.
Unplug the lamp with power wires, hold the bottom of the lamp by hand and move it as directed by the arrow using force to make the
other end of the lamp off the holder. At last take the lamp out of the bottom of the head. Before placing a new lamp inside , plug the
lamp with power wires tightly. Lamp placement and its removal are in opposite orders
Note: Don’t touch the internal surface of the reflector and the burner of the lamp with bare hands so as not to impair the beam output.
While lamp’s installation, do not damage the metal wire around the burner.
Put back th
e
lamp
cover, bob-weight block, airflow cover and tighten all screws.
Important: Please read "Instructions " enclosed with the lamp carefully before its use.
8 screws for
lamp cover
lamp
1
2
3
4
4 screws for
airflow cover
4 screws for
bob-weight block