background image

  4590V101-UK 7

Connection of ConfigMate 4590 to a PC in Docking Mode

Connection of ConfigMate 4590 to a PR 4000/9000 Device

Note: 

By default, the Programming Display 4501 / Communication Enabler 4511 will display the desired process value when 
connected to a device, either directly or via ConfigMate 4590.

   To upload a configuration from a 3000/4000/9000 device to the 4501/4511, you must manually go into the Memory 

Menu of the 4501/4511 and SAVE from the target device into the 4501/4511.

   To download a configuration to a 3000/4000/9000 device from the 4501/4511, you must manually go into the Memory 

Menu of the 4501/4511 and LOAD to the target device from the 4501/4511.

For further details, please refer to the relevant manual for the target device.

Summary of Contents for 4590

Page 1: ...FORMANCE MADE SMARTER Product Manual 4590 ConfigMate USB communications interface TEMPERATURE I S INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No 4590V101 UK From ser no 110404001 ...

Page 2: ...allows for local monitoring of process values device configuration error detection and signal simulation The next generation our 4511 Remote Operator Interface ROI does all that and more adding remote digital communications via Modbus RTU while the analog output signals are still available for redundancy With the 4511 you can further expand connectivity with a PR gateway which connects via industr...

Page 3: ...Mode 6 Connection of ConfigMate 4590 to a PC in Docking Mode 7 Connection of ConfigMate 4590 to a PR 4000 9000 Device 7 Adaptor Mode 8 Connection of ConfigMate 4590 to a PR 3000 Device 8 USB and PReset installation Docking Mode Only 8 Technical characteristics 8 System requirements 8 Installation of PReset 9 Configuration of USB communication in PReset 9 ...

Page 4: ...ng risk of explosion hazard To avoid risk of explosion and injury Do not use this equipment when a flammable or combustible atmosphere is present Do not replace batteries unless area is known to be safe Use 3 x 1 5 V TYPE AAA batteries only and insert correctly as stipulated in battery compartment Warning risk of electrical shock To avoid risk of electrical shock and injury Do not disconnect the c...

Page 5: ...eratures mechanical vibrations and shock and rain and heavy moisture Normal operation Only technicians who are familiar with the technical terms warnings and instructions in the manual and who are able to follow these should connect the device Should there be any doubt as to the correct handling of the device please contact your local distributor or alternatively PR electronics A S www prelectroni...

Page 6: ... note For connection to a PC the USB B to USB A cable must be used In docking station mode the 4590 will be powered from the PC s USB power source no batteries are required The 4501 4511 display will indicate USB line communication with a very short blink when uploading or downloading configurations from to the 4501 The selected 3000 4000 and 9000 device configurations can only be viewed in the Pr...

Page 7: ...rectly or via ConfigMate 4590 To upload a configuration from a 3000 4000 9000 device to the 4501 4511 you must manually go into the Memory Menu of the 4501 4511 and SAVE from the target device into the 4501 4511 To download a configuration to a 3000 4000 9000 device from the 4501 4511 you must manually go into the Memory Menu of the 4501 4511 and LOAD to the target device from the 4501 4511 For fu...

Page 8: ...d be exchanged To extend battery life the 4590 will automatically detect if it is not in use and will consequently shut itself down to conserve battery power Battery life in Adaptor Mode is approximately 1 year of daily use depending upon battery type Connection of ConfigMate 4590 to a PR 3000 Device USB and PReset installation Docking Mode Only The USB communication is supported by Windows Window...

Page 9: ...t software from www prelectronics com downloads software preset software Note that this is in the form of a zip file 2 Unzip the file to the desired location 3 To start the installation double click the setup exe file When the installation program has been started on screen guidelines will guide you through the rest of the installation The complete installation guide for PReset can be downloaded f...

Page 10: ...entation We are headquartered in Denmark and have offices and authorized partners the world over We are a local business with a global reach This means that we are always nearby and know your local markets well We are committed to your satisfaction and provide PERFORMANCE MADE SMARTER all around the world For more information on our warranty program or to meet with a sales representative in your r...

Page 11: ...andards for products communicating monitoring and connecting our customers process measurement points to their process control systems Our innovative patented technologies are derived from our extensive R D facilities and from having a great understanding of our customers needs and processes We are guided by principles of simplicity focus courage and excellence enabling some of the world s greates...

Reviews: