background image

Automatic Model

Owners

 

Operating

 

Manual 

t h e   u lt i M at e   h O M e O w n e r s   g u i d e   t O

  w at e r   c O n s e r vat i O n   at   h O M e

Summary of Contents for H2grO - Greywater for Gardens

Page 1: ...Automatic Model Owners operating Manual the ultimate homeowners guide to water conservation at home...

Page 2: ...has been obtained Your garden will benefit from the investment and every decision to reuse greywater relieves the pressure on Australia s precious water resources The system is intended to make greyw...

Page 3: ...rk so you need to decide which are the best sources of greywater in your home We suggest that you use greywater from baths and showers in preference to basin and laundry water as it is more dilute and...

Page 4: ...ywater to sewer when cleaning baths and shower recesses Use liquid soap and detergent in preference to bar soap or powders and select brands that are low in Phosphorus and Sodium Seek advice from your...

Page 5: ...steel filter screen which removes lint hair and large particles after which it collects in a pumpwell When the level rises in the pumpwell a float switch activates the pump and the greywater that has...

Page 6: ...op a fault the greywater level will rise in the pumpwell overflow through a weir below the filter screen and discharge safely to sewer 5 In the unlikely event that the council sewer becomes blocked an...

Page 7: ...valve to enable you to send greywater directly to four separate garden outlets and one outlet to waste sewer It is operated electrically from a controller located within your bathroom or laundry Elect...

Page 8: ...tional Electric 5 position Diverter Valve Irrigation Outlet 4 Electric Model 1 Manual Model Non Return Valve Electrical Cables Grommets for inlet pipes Handle and safety latch Overflow relief grate OR...

Page 9: ...e connected to one pipe and flow to the H2 grO diverter while the basin floor waste and toilet may be combined and flow to sewer The lid is fitted with a pop out grate and may be used as an overflow r...

Page 10: ...rge pipe to 10m Reference AS NZS 3500 2 2003 Clause 3 3 3 Table 4 1 and Appendix D 4 What is the Maximum distance you can run vented 65mm 50mm pipe Answer There is no limit if the vent is installed in...

Page 11: ...the surrounding ground 100mm concrete 100mm concrete Holes in back wall Hole in side wall Raised a minimum of 75mm above ground Step Two To provide entry of the inlet pipe the plumber makes a hole int...

Page 12: ...tely 100mm Rubber Seal Adaptor supplied 100mm DWV Trap not supplied Step Four Connection of the moulded polyethylene H2 grO housing to a trapped DN100 sewer drain is achieved with a 100mm Rubber Seal...

Page 13: ...A fuse is fitted within the electrical enclosure inside the H2 grO housing This fuse protects the pump If the fuse fails replace it with a 20x5mm 6 3 Amp item If replacement fuse blows there could be...

Page 14: ...his fuse protects the pump If the fuse fails replace it with a 20x5mm 3 15 Amp fast blow type item If replacement fuse blows there could be a fault with the pump or power supply DO NOT fit another fus...

Page 15: ...se Security or irrigation control cable a minimum of 4 core x 0 5mm must be used for this connection d Extra Room Switch Optional This switch is available as an option This switch has to be connected...

Page 16: ...Switch Optional Control cable junction box Cables from H2 grO housing Rear view of Extra Room Switch Optional Rear view of Controller Cable denotes control cable not supplied use security or irrigatio...

Page 17: ...e The screen will display USER TO WASTE Figure 1 If there are any problems have your licensed electrical contractor check the connections 7 Check the operation of the pump Fill the pumpwell with water...

Page 18: ...he optional Extra Room Switch confirm that the indicator light changes between GARDEN and WASTE each time the switch is pressed Operate the pump and check the valve redirects to the outlet nominated b...

Page 19: ...ods required Allow one pod for each large shrub for annuals allow one pod for each square metre of the garden to be irrigated The ideal number of pods per zone is between 15 and 25 Trial and error may...

Page 20: ...annual maintenance 25mm purple H2 grO pipelines should be buried under the soil or concealed beneath a thick layer of garden mulch Installing the pods Using a hole punch make a hole in the 25mm purpl...

Page 21: ...when pressed again The Automatic H2 grO can be run in a manual or automatic mode and can be changed at any time by the operator Manual Mode Check the screen display and ensure the valve is diverted to...

Page 22: ...rected to this outlet in case an outlet is not connected The maximum value that can be set to an outlet is 980 LITRES Press the OK button to activate 060LITRES TO G1 then press the up or down button a...

Page 23: ...ly and the bar graph will start at 0 again In Figure 4 and 5 the bottom line of the display shows the cursor pointing to GO TO WASTE so that the operator can quickly redirect the valve to the waste se...

Page 24: ...ter screen or pump from the unit Remove the filter screen from the H2 grO housing and clean it well After isolating the H2 grO unit from its power supply disconnect and lift the pump from the pump wel...

Page 25: ...heck that the 6mm flexible tube to the pods is not blocked Controller or Extra Room Switch does not function Check that power is connected and that the isolation switch is in the on position Check tha...

Page 26: ...erate and maintain the warranted product in accordance with the instructions provided in this owner s manual Items or service that is normally required to maintain the product eg Subsurface irrigation...

Page 27: ...oration Pty Ltd 40 Prosperity Place Geebung QLD 4034 Ph 07 3865 3699 Fax 07 3857 0058 Email sales ppi com au www h2gro com au www homeirrigation com au www ppi com au Date 21st October 2008 Code ZM H2...

Reviews: