Dip switch Configuration
Key 1 sets the state of the relay: ON = NC (normally closed) and OFF = NO
(normally open).
Key 2 sets the pulse retention time: ON = 2 seconds and OFF = 0.5 seconds.
Key 3 sets the immunity mode: ON = high immunity and OFF = normal immunity.
The "Selection" function (key 4 of the DIP Switch) configures the detection in
unidirectional mode, that is, the detection of movements occurs only in the
direction of approximation.
NOTE:
This function helps to inhibit the false shots caused by natural movements
of some parts of the automatic door itself, such as the belt, the rail, etc.
ON = function enabled
OFF = disabled function
Application Example: When passing through the door, only the first sensor,
be it the internai radar or the externai radar, will detect the movement. As the
second sensor will not activate, the automatic door may Glose at the exact time of
scheduled automatic closing, aiding in the optimization of air conditioning and in
the consumption of the system.
NOTE:
Set up with high immunity in environments where rain or other light movement may
occur in front of the sensor to prevent false shots. This setting makes the sensor
"slower".
Connection diagram in Command Board – Radar
Fixing the radar to the cover
1. Radar must be fixed in the middle of the passageway.
2. Pass the wire through the larger hole, from the outside to the inside, and secure
with a fastener and clamp that comes with the kit.
3. Determine the location for fixing the external radar, making the fixing holes and
passing the wire.
EXTERNAL
RADAR
INTERNAL
RADAR
Gray cable
Internal connector (polarized)
Drilling template
Radar
Red = 15V
Brown = GND
Oranje = GND
Oranje
Yellow = Radar
Yellow
Brown
Red