TROUBLESHOOTING 

 

The table below contains useful information on some PROBLEMS — SYMPTOMS, 

PROBABLE CAUSES AND POSSIBLE SOLUTIONS which might affect your operator. 

Before intervening on the system (maintenance, cleaning), always disconnect the 

product from the mains power supply.

SYMPTOMS

PROBABLE CAUSE(S)

ACTION(S)

Manouver fails to 

start

A) No power supply

B) Open / Blown fuse

C) Gate jammed

D) Defective limit switch

A) Ensure that the power cable is 

correctly inserted in the power 

outlet.

B) Substitute the fuse for another 

one with the same specifications

C) Ensure there are no obstruction 

on the gate travel

D) Substitute the (analog and/or 

digital) limit switch system

Motor won't run

A) Reversed wiring

B) Gate or operator jammed

A) Check the wiring

B) Change to manual mode and 

check it separately

Control board 

does not accept a 

command

A) Blown fuse

B) No power supply

C) Defective remote control / Low 

battery

D) Remote control range

A) Substitute the fuse for another

B) Ensure that the power cable is 

correctly inserted in the power 

outlet

C) Check and substitute the battery

D) Check the position of the 

receiver's antenna and, if necessary, 

try adjusting it, if you think the 

signals to be weak

Motor only runs in 

one direction

A) Reversed wiring

B) Reversed limit switch system

C) Defective control board

A) Check the motor wiring

B) Reverse the limit switch 

connector (analog and/or digital)

C) Substitute the control board

Summary of Contents for PIVO HOME

Page 1: ...this manual first Technical Manual P09834 11 2021 Rev 0 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406 200 Br...

Page 2: ...t the local grid power complies with the technical data appearing on the gate s label Do not connect the operator to the source ofpoweruntiltheinstallation maintenance or servicing is over Proceed the...

Page 3: ...PIVO HOME JETFLEX TYPE OF GATE OPERATOR Swing Swing Swing Swing MOTOR Single phase Single phase JetFlex JetFlex POWER SUPPLY 127V 220V 127V 220V 127V 220V 127V 220V RATED FREQUENCY 60 Hz 60 Hz 60 Hz 6...

Page 4: ...e installation Check the effort required to open close the gate One must be able to perform it smoothly on the entirety of its movement In order to check such effort move the gate 80 cm 2 63 ft away f...

Page 5: ...ge and at the desired height to mount the operator according to the picture below Step 3 Weld the fastening base according to the instructions pictures below INSTALLATION FOR OPERATORS WITHOUT MECHANI...

Page 6: ...ccording to the instructions pictures below Step 5 Fit the gear motor to the fastening base tighten the M10 x 45 screw and fix it by means of a M10 hex nut provided according to the picture below FAST...

Page 7: ...x 6 screws fixed on the reeds and connect it to the control board Before running the operator one must screw the operator housing by means of the 4 provided 3 5 x 16 mm screws CONTROL UNIT Check on th...

Page 8: ...D Substitute the analog and or digital limit switch system Motor won t run A Reversed wiring B Gate or operator jammed A Check the wiring B Change to manual mode and check it separately Control board...

Reviews: