background image

COMFORT whit SECURITY

COMFORT whit SECURITY

PREPARATION OF THE GATE BEFORE AUTOMATION

Before installation of the machine, check rolling, following the instructions

below:

1º Step:

 Move gate leaf manually and see the required

effort.  Gate should move with ease.

2º Step: 

Move leaf back manually and check whether

the effort required was the same as the previous
operation.

Gate should have a strong structure and as

much as possible straight.

Pulleys should be of a diameter according to

gate dimensions. They also should be in rolling

perfect conditions and assembled in a way that the gate leaf has
stability during its trajectory. We recommend pulleys have at least

120mm of diameter.

Figures beside represent two types of tracks and pulleys used.

The system that uses straight section (

figure A

 – angle iron) shows

more resistance, therefore, more wear. On the other hand, the system

that uses round section (

figure B

) allows a better gate movement

and less resistance to the gate operator.

3º Step:

 Check if gate leaf does not stop during opening and closing

trajectory.

Gate rolling track should be perfectly straight and

occasionally cleaned from any element or dirt that
complicates pulleys sliding, as it is showed on picture

beside:

Observation:

 The information above is very important

because it can be prejudicial for gate operator

performance.

TECHNICAL CHARACTERISTICS

Equipment Dimensions

Source: ........................... 110/220V

Frequency: ..................... 50/60Hz

Rotation: ......................... 1450(50Hz)/ 1750(60Hz)

Reduction: ...................... 30:1

Protection: ...................... IP 44

Capacitor: ....................... 8uFx400V/ 20uF x 250V

Isolation: ......................... F

Packing dimensions: ...... 260 x 240 x 317 mm

Gate operator weight: ..... 9Kg
Max. gate weight : .......... 300Kg

INSTALLING THE RACK

1º Step: 

Set the machine on manual mode (see page 6),

open gate completely, and place rack on gear in a way

that it has 2mm between teeth. Make the fixation on leaf
every 30 or 40 cm using a welder or screw in the entire

extension of the gate leaf.

Observation

:

In case the gate leaf is crooked,

provide shimes to assure rack
alignment. In certain cases, the rack will

exceed the leaf length. If that is the case,

provide an L-bracket so it does not jump
the track during the machine start.

2º Step:

 Feed control unit with 220v,

according to equipment voltage, to

record remote controls as it is

explained in this manual.

-With the gate on manual mode, place leaf in

the middle of course and switch equipment to

automatic mode.

-Turn power off temporarily and turn it on again;

activate remote control and check if gate opens

obeying the command. If gate opens, it will show that
rotation direction is correct. In case situation described

previously is not occurring, switch motor’s Red and

Black wire.

3º Step:

 Magnets Installation – with the

gate closed, place magnet support
facing the REED, open gate

completely and place the other

magnet facing the REED. Turn mo-
tor on and do the final test,

observing if REEDs are turning off

correctly. If it is necessary switch
plate connector.

After installing magnets

support, do fine adjustments and if
necessary use the opening situated

on magnet support to move the

magnet position, according to
illustration beside.

L-bracket detail

Page 

03

Page 

04

Summary of Contents for Eurus Custom

Page 1: ...MFORT whit SECURITY COMFORT whit SECURITY www ppa com br PPA Portas e Port es Autom ticos Ltda Av Labieno da Costa Machado n 7 3526 Distrito Industrial CEP 17 400 000 Tel 0 14 3407 1000 Gar a SP Brasi...

Page 2: ...tons 9 Blow out image 10 e 11 Parts List 12 Memorizing Adjustments of Trimpots and Virtual Fuse 13 Types of Virtual Fuse Protection 13 Adjusting Trimpots 14 Configuring Jumpers 15 Auto light timer LG...

Page 3: ...eduction 30 1 Protection IP 44 Capacitor 8uFx400V 20uF x 250V Isolation F Packing dimensions 260 x 240 x 317 mm Gate operator weight 9Kg Max gate weight 300Kg INSTALLING THE RACK 1 Step Set the machin...

Page 4: ...nd of track or at the end of O C time 5 When the gate is closing and it meets an obstacle Control unit with present course the gate stops and opens totally Control unit without present course the gate...

Page 5: ...nic lock transmitter is lost and the control unit has lock on it will be necessary to call anAuthorized Technical Service TURNING OFF ALL BUTTONS Steps to turn off all buttons Step 1 Keep jumper HRF c...

Page 6: ...COMFORT whit SECURITY COMFORT whit SECURITY Page 08 Page 09 BLOW OUT IMAGE EURUS CUSTOM...

Page 7: ...on again continuing the previous trajectory IMPORTANT The automatic restart occurs 3 consecutive times max LISTA DE COMPONENTES EURUS CUSTOM KIT Sliding Electronic Custom Incorp Radio Frequency 110vca...

Page 8: ...in motion try to stop it and check if the degree of sensitivity is the desired one In case of being too sensitive adjust the trimpot Sensor again turning to side and repeat this step IMPORTANT Contro...

Page 9: ...UTO LIGHT TIMER LG Garage light module Light is turned on every time gate is in motion Every time motor is turned off the garage light is timed for 2 minutes SIGNALING LED FUNCTIONS SN It has the purp...

Page 10: ...esponsibility of consumer The substitution or repair of equipment does not prolong the warranty This warranty will be terminated if Product is damaged by accidents or acts of God as lightning floods m...

Reviews: