COMFORT whit SECURITY
COMFORT whit SECURITY
Page
14
Page
15
ADJUSTING THE TRIMPOTS
TRIMPOT FORCE
Function:
To adjust motor power applied on gate (Electronic clutch).
Opening and Closing:
Same adjustment.
‘ + ’
position: More power
‘ - ‘
position: Less power
Steps for motor power adjustments:
1. With motor turned off, adjust the Trimpot Force to position
‘-‘
and the trimpot
Sensor in the position
‘+’
;
2. Memorize trimpots (see page 17);
3. Activate motor;
4. Check if gate opens and closes completely. If not, adjust trimpot force again,
turning to
‘+’
side. Repeat steps 2, 3, and 4.
TRIMPOT SENSOR
Function:
To adjust the anti-crushing security system sensibility.
Opening and Closing:
one adjustment for opening and one for closing.
‘ + ’
position = more sensitive
‘ – ‘
position = less sensitive
Steps for adjustments of motor sensor:
1.
With motor turned off, adjust the Trimpot Sensor to position
‘ + ‘
;
2.
Memorize trimpots;
3.
Activate motor;
4.
Check if gate opens and closes completely. If not, adjust the trimpot Sensor again,
turning to
‘ - ’
side. Repeat steps 2, 3, and 4.
5.
With the gate in motion, try to stop it and check if the degree of sensitivity is the
desired one. In case of being too sensitive, adjust the trimpot Sensor again,
turning to
‘ – ‘
side and repeat this step.
IMPORTANT
:
- Control unit with end of course: anti-crushing security system with auto
reverse sensitivity.
- Control unit without end of course: anti-crushing security system with
immediate shut off system.
TRIMPOT BRAKE
Function:
To stop the gate at the moment it reaches the reeds working as a
gate inercia eliminator.
Opening and Closing:
same adjustment.
DC Brake: Smoth Instant Brake
TPO Brake: Soft timed Brake
Position ‘ + ’ = Longer Braking time (TPO)
Position ‘ – ‘ = Lesser Braking time (TPO)
CONFIGURING JUMPERS
EXTERNAL RECEPTOR
Function: Hook up for external RF receptor.
1
- 22VCA
2
- 22VCA
3
- GND
4
– CMD
JUMPER A/S
Function: To select control unit mode of working operation: automatic mode
or semi-automatic mode.
Jumper A/S Closed:
Semi-automatic mode.
Jumper A/S Open:
Automatic mode
JUMPER HC
Function: It allows the recording of the electronic lock transmitter.
Jumper HC Closed:
Yes
Jumper HC Open:
No
TRIMPOT PAUSE
Function:
To adjust control unit pause timing when it is in automatic
mode.
Position
‘ + ’
= Maximum time of 1 minute
Position
‘ – ‘
= Minimum time of 1 second