4
FUNCTIONING
In the factory default, only the wired sector, ie, the closing limit switch (FCF) is enabled for monitoring the gate
as specified in the table and its parameters.
Wireless sectors (sectors 1 through 8) are disabled by factory default.
When the board is energized and the gate is closed with the closing limit switch (FCF) activated or when the
gate closing cycle ends with the closing limit switch (FCF) sensor activated and the gate alarm function is
enabled the alarm will be armed after auto-arm time is reached. After arming the board, the garage light and
the PGM output (PGM TRV MODE selected as Siren) will be activated for a time of 0.5 seconds only once. for
5 sec and off for 1 sec.
To
disarm
the alarm, it will be necessary that the gate is closed with the limit switch sensor activated by the
gate magnet and also that the activated button of the transmitter is configured as Arm / Disarm. After the
board recognizes and validates the button as Arm / Disarm the alarm will be disarmed and the garage light
and PGM output (PGM TRV MODE selected as Siren) will activate for a time of 0.5 seconds repeated twice.
To
arm
the alarm, it will be necessary that the gate is closed with the limit switch sensor activated by the gate
magnet and also that the activated button of the transmitter is configured as Arm / Trip. After the board re
-
cognizes and validates the button as Arm / Disarm, the alarm will be armed and the light The garage door and
the PGM output (PGM TRV MODE selected as Siren) will be activated for a time of 0.5 seconds once.
When the board receives an opening command with the valid access button, the opening cycle is started and
the alarm is temporarily disarmed until the gate ends the closing cycle with the closing limit switch sensor ac-
tivated by the magnet. After the closing cycle, the arming time starts and when completed will arm the alarm
again. The garage light and the PGM output (PGM TRV MODE selected as Siren) will be activated for a time
of 0.5 seconds once.
With the gate closed and the alarm in the armed state and if there is a violation or theft of the gate in which
the magnet moves away from the closing limit switch sensor or if the devices in the wireless sectors send the
radio frequency signal to the board that will go into an alarm state where it will trigger the output PGM (TRV).
To cancel the gate alarm status it will be necessary to command a valid gate opening button.
NOTE:
For programming the alarm features it will be allowed if the gate is open.