23
When the gate is closed and the alarm is disarmed and upon receiving a command from the transmitter with
the button set to arm/disarm, the PGM and LG outputs will be turned on once for a period of 0.5 seconds and
the alarm will be armed after user-defined arming time.
Disarmed alarm
Arm time
LG output
PGM output
Arm by transmitter
button
Timing Arm
Arm time=0
Monitor sector with
the gate closed
2.0 sec
2.0 sec
0.5
sec
0.5