Page 7 of 32
3.
INSTALLATION
Not withstanding their limited scope, the appliance should be installed in accordance with the relevant
provisions of any National Gas Safety (Installation and Use) Regulations. Due account should also be
taken of any obligations arising from any National Health and Safety at Work Regulations, National and
Local Building Regulations and National Electrical Wiring Regulations. The appliance must be installed,
and where necessary, converted for use on other gases, by a qualified installer.
3.1
Suspension
3.1.1
The appliance should be located with respect to building construction and other equipment to permit
access to the appliance for servicing etc.
3.1.2
For suspending the appliance it is recommended that suitable protected welded chain (Ø3mm x 65 links
per m) or Ø8mm min mild steel drop rods and suitable brackets are used. Attach the chains or drop rods
to the hanger brackets where shown (see section 4). Providing at least Ø5mm closed link hooks are used
chains may be attached directly to the hanger brackets.
3.1.3
The appliances may be mounted horizontally or at a rec ommended angle of 30
0
maximum to the horizontal
as shown below.
Fig. 5
3.1.4
Minimum clearance from combustibles:-
Fig 6
Horizontal Mounting
Neon Lights
Latch
Neon Lights
Angle Mounting
(recommended to 30°)
30°
Latch
END
END
ABOVE (CEILING)
ABOVE (CEILING)
BELOW
BELOW
SIDE
SIDE
FRONT
REAR