Powrmatic PK-A1K030 User, Installation & Servicing Manual Download Page 4

page no. 4 of 16     

    

 PQ-A

 Range   Users, Installation & Servicing Instructions  Doc Ref M308 issue 1.1 May 2019. 

The Powrmatic A-Range of high powered heaters have 

been designed and manufactured at the highest standard 

to provide radiant heat to commercial and industrial 

environments at high level and are available in heat 

outputs of 1kW to 18kW.

The A-Range boasts all of the performance benefits 

associated with full quartz shortwave technology 

while providing an economic solution for industrial 

and commercial heating requirements. It offers all the 

convenience of electricity together with very low running 

costs when compared to other forms of heating.

The range of quartz infrared heaters to suit any 

application requiring a reliable heating solution including 

commercial, domestic, outdoor and industrial heating 

with reliability, durability and virtually maintenance free 

benefits.

Profile Design

Use of dedicated extruded aluminium profile. This helps 

the powerful heaters stay cool during running time. The 

aluminium profile is lightweight and eliminates rusting 

and discoloration.

Unique designed integral aluminium heat sinks 

additionally help keep the heater cool and improve 

reliability compared with inferior alternatives on the 

market.

Shortwave Technology

full shortwave technology is noiseless and contributes 

to no atmospheric pollution and no movement of dust 

or other particles, which can be important in many 

environments.

Parabolic Reflectors

The unique deep, smooth parabolic reflectors produced 

using high grade anodised aluminium provides superior 

consistent reflectivity through 100% of the reflector. This 

provides intense uniformed heat coverage across a larger 

area. The 0.8mm thick reflector effortlessly projects 

heat forwards and in turn provides unbeatable heat 

performance.

Durability

hard wearing / durable, reliable and designed to stand 

hours of consistent commercial / industrial use.

It has been engineered to dissipate heat in order to keep 

the body running cool which in turn increases life of the 

product and its components.

Installation Flexibility

dedicated bracketry provide flexibility when installing on 

side walls or overhead. also the swivel bracket (selected 

models) offer directional heat where required which 

makes the Apollo an easy to install flexible heating 

solution.

Energy Saving Controls

compatible with energy saving controllers which 

provides both controllability of heat output and energy 

saving benefits to all models including the three phase 

configuration which can be variably controlled.

IMPORTANT
Service and Maintenance Engineers shall 

ensure that replacement items are fitted, 

adjusted and set in accordance with the 

data and detail set out in these instructions. If in doubt 

consult Powrmatic Technical Department.

If the heater has not been left operational 

proceed as follows. 

The following preliminary checks should be made before 

lighting the heater(s)

a) Ensure that the ELECTRICAL supply to the controller/ 

external switch/heater is switched ON.

b) Ensure there is no foreign objects inside the grille or 

covering the body of the heater.

Switch ON via the external switch/push button timer/

external controller. To deactivate, switch OFF via the 

external switch/push button timer/external controller.

To maintain correct, efficient, reliable and safe operation 

of the heater it must serviced by a qualified person.

Free access must be maintained to and around the heater 

for servicing purposes and the air supply to the heater 

must not be restricted in any way. Combustible materials 

must not be stored adjacent to the heater.

All Powrmatic heaters use electricity to power them. 

It would be hazardous to tamper with or attempt to 

service unless you are a competent person in the field of 

Electrical work.

If you have any safety questions reference the servicing 

and installation of any of our heaters please do not 

hesitate to contact our head office for expert advice. Your 

safety is paramount to us.

Summary of Contents for PK-A1K030

Page 1: ...w w w p o w r m a t i c c o u k PQ A User Installation Servicing Manual Issue 1 1 May 2019 Doc Ref M308 Issue 1 1 May 2019...

Page 2: ...f Conditions of Guarantee 1 The heater must have been installed by a competent qualified installer and in accordance with the manufacturer s instructions building regulations and local regulations 2 T...

Page 3: ...s Doc Ref M308 issue 1 1 May 2019 Title Section Contents Page User Instructions 4 Pre Installation 1 1 Introduction 4 Dimensions 6 1 2 Technical data 9 Installation 2 1 Installation 10 2 2 Maintenance...

Page 4: ...dissipate heat in order to keep the body running cool which in turn increases life of the product and its components Installation Flexibility dedicated bracketry provide flexibility when installing on...

Page 5: ...en recently used Remove the plug from the mains socket or disconnect pole switch during installation cleaning and or replacing the element and always ensure that the element is cool Do not handle the...

Page 6: ...0 273 n a n a n a n a PQ A1B020 030 040 390 420 102 80 194 45 PQ A1C030 045 060 525 555 PQ A3C030 045 060 A C D B SIDE FRONT BACK MESH PATTERN NOT SHOWN A C D B E F H G MESH PATTERN NOT SHOWN SIDE FRO...

Page 7: ...issue 1 1 May 2019 SIDE FRONT BACK FRONT BACK A B C D E F G J PQ A1J020 030 040 857 255 110 285 102 n a n a 435 PQ A3E060 090 120 630 663 102 n a 199 A C D B J MESH PATTERN NOT SHOWN A C D B E J G E M...

Page 8: ...J G A C D B E F J SIDE FRONT BACK SIDE FRONT BACK A B C D E F G J PQ A1K030 045 060 1282 255 110 285 102 215 199 860 PQ A1K030 045 060 285 102 215 199 860 PQ A3L060 090 120 441 473 150 213 199 860 PQ...

Page 9: ...1 17 4 2 5 0 15 1 0 857 255 110 6 0 PK A1K030 230 3 1 0 3 0 1 13 0 2 5 0 15 1 5 1282 255 110 8 0 PK A1K045 230 3 1 5 4 5 1 19 6 2 5 0 15 1 5 1282 255 110 8 0 PK A1K060 230 3 2 0 6 0 1 26 0 3 0 0 15 1...

Page 10: ...the bracket See diagram below 2 1 1 Mounting Chain Hung Warning Switch off unplug the heater from the mains supply when mounting or adjusting the heater position The heater is suitable for installati...

Page 11: ...1B020 The wires in the mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live Since the colours of the wires in the mains lead of this appliance m...

Page 12: ...ger marks will burn into the lamps quartz glass causing premature failure 2 2 1 REPLACING A LAMP Warning Unplug switch off from the mains power to the heater power before any attempts are made to repl...

Page 13: ...reflector or touch the new lamp with the hands see caution 8 Replace the lamp holding clips Make sure they are firmly in place over the white ceramic ends of the lamp 9 Refit the male and female conn...

Page 14: ...page no 14 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Page 15: ...page no 15 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Page 16: ...t Dublin 24 tel 353 0 1452 1533 fax 353 0 1452 1764 e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of...

Reviews: