Powrmatic PK-A1K030 User, Installation & Servicing Manual Download Page 12

page no. 12 of 16     

    

 PQ-A

 Range   Users, Installation & Servicing Instructions  Doc Ref M308 issue 1.1 May 2019. 

Note: 

 It is very important that the 

replacement lamp is exactly the same as the 

one the heater was supplied with. 

Failure to fit the exact same type could cause the heater 

to fail or even become dangerous especially when used in 

an outdoor environment. 

Please contact Powrmatic Limited to purchase your 

replacement lamp and state the model  

number of the heater you wish  

to fit the lamp to.

Note: 

Your new lamp(s) should 

NOT

 be handled 

with bare hands. Remove finger marks with a 

soft cloth and methylated spirits or rubbing 

alcohol. Finger marks will burn into the lamps 

quartz glass causing premature failure.

2.2.1. REPLACING A LAMP

Warning:  

 Unplug/switch off from the 

mains power to the heater power before any 

attempts are made to replace the lamp. 

Contact your service agent for the correct replacement 

lamp quoting model type and rating from rating label. 

It is important that you read through the lamp 

replacement procedure before commencing.

1. Disconnect the power supply to the heater.

2. Remove guard (where fitted) by flexing one end and 

releasing from it’s locating holes on the lamp to be 

replaced.

3. Remove either the three screws from  

both front side covers on smaller  

models, or remove the screws from  

both sides the middle cover(s) on 

longer models by as shown below.

4. Locate the lamp wire by the terminal and release from 

tab. Repeat at other end.

Summary of Contents for PK-A1K030

Page 1: ...w w w p o w r m a t i c c o u k PQ A User Installation Servicing Manual Issue 1 1 May 2019 Doc Ref M308 Issue 1 1 May 2019...

Page 2: ...f Conditions of Guarantee 1 The heater must have been installed by a competent qualified installer and in accordance with the manufacturer s instructions building regulations and local regulations 2 T...

Page 3: ...s Doc Ref M308 issue 1 1 May 2019 Title Section Contents Page User Instructions 4 Pre Installation 1 1 Introduction 4 Dimensions 6 1 2 Technical data 9 Installation 2 1 Installation 10 2 2 Maintenance...

Page 4: ...dissipate heat in order to keep the body running cool which in turn increases life of the product and its components Installation Flexibility dedicated bracketry provide flexibility when installing on...

Page 5: ...en recently used Remove the plug from the mains socket or disconnect pole switch during installation cleaning and or replacing the element and always ensure that the element is cool Do not handle the...

Page 6: ...0 273 n a n a n a n a PQ A1B020 030 040 390 420 102 80 194 45 PQ A1C030 045 060 525 555 PQ A3C030 045 060 A C D B SIDE FRONT BACK MESH PATTERN NOT SHOWN A C D B E F H G MESH PATTERN NOT SHOWN SIDE FRO...

Page 7: ...issue 1 1 May 2019 SIDE FRONT BACK FRONT BACK A B C D E F G J PQ A1J020 030 040 857 255 110 285 102 n a n a 435 PQ A3E060 090 120 630 663 102 n a 199 A C D B J MESH PATTERN NOT SHOWN A C D B E J G E M...

Page 8: ...J G A C D B E F J SIDE FRONT BACK SIDE FRONT BACK A B C D E F G J PQ A1K030 045 060 1282 255 110 285 102 215 199 860 PQ A1K030 045 060 285 102 215 199 860 PQ A3L060 090 120 441 473 150 213 199 860 PQ...

Page 9: ...1 17 4 2 5 0 15 1 0 857 255 110 6 0 PK A1K030 230 3 1 0 3 0 1 13 0 2 5 0 15 1 5 1282 255 110 8 0 PK A1K045 230 3 1 5 4 5 1 19 6 2 5 0 15 1 5 1282 255 110 8 0 PK A1K060 230 3 2 0 6 0 1 26 0 3 0 0 15 1...

Page 10: ...the bracket See diagram below 2 1 1 Mounting Chain Hung Warning Switch off unplug the heater from the mains supply when mounting or adjusting the heater position The heater is suitable for installati...

Page 11: ...1B020 The wires in the mains lead are coloured in accordance with the following code Green and yellow Earth Blue Neutral Brown Live Since the colours of the wires in the mains lead of this appliance m...

Page 12: ...ger marks will burn into the lamps quartz glass causing premature failure 2 2 1 REPLACING A LAMP Warning Unplug switch off from the mains power to the heater power before any attempts are made to repl...

Page 13: ...reflector or touch the new lamp with the hands see caution 8 Replace the lamp holding clips Make sure they are firmly in place over the white ceramic ends of the lamp 9 Refit the male and female conn...

Page 14: ...page no 14 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Page 15: ...page no 15 of 16 PQ A Range Users Installation Servicing Instructions Doc Ref M308 issue 1 1 May 2019 Notes...

Page 16: ...t Dublin 24 tel 353 0 1452 1533 fax 353 0 1452 1764 e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of...

Reviews: