8
Storage of Equipment
1. Store extractor indoors in a dry area.
2. Recovery and solution tank should be empty and clean when the extractor is not in use.
3. Leave the recovery lid and drain hose open to air out the recovery tank.
4. Do not store in freezing temperature.
5. A small amount of windshield washer fluid may be left in the pump and internal solution line
for protection against freezing.
Warnings
1. Do not break off or pull the grounding prong on the plug.
2. Do not attempt repair on a machine that is under warranty unless instructions to perform it
by an authorized shop are obtained from the factory.
3. Do not use citrus-based (D-Limonene) cleaners in this machine.
4. Do not use cleaning chemicals in this machine except those recommended for steam-type
extraction equipment. The use of any chemicals with abrasive additives voids the
warranty.
5. Do not use any replacement parts except those specified on the parts list. Performance of
the machine could be affected if substitutions are made.
6. Do not use water in excess of 140° F (60° C) through the pump system. It could damage the
seals and polyprophene casing of the diaphragm pump.
7. Follow maintenance schedule strictly.
8. Failure to comply with the above warnings instructions will void the warranty.
Summary of Contents for PE060-G15-U
Page 1: ...Pulsar Extractor OPERATOR S MANUAL PE060 G15 U ...
Page 11: ...11 NOTES ...