background image

3

INTRODUCTION

Warranty

Within 30 days of purchase, to activate product warranty, 
go to: 

https://www.powr-flite.com/warranty-registration

 

Warning Labels

Prior to operating the unit, read and understand completely this 
owner’s manual paying special attention to warning labels. These 
labels indicate a potentially hazardous situation that could result in 
death or serious injury if not avoided. Use only as described in this 
manual. 
 

Flammability Warning

NEVER fill unit with flammable chemicals.  Do NOT use 
in an area where flammable fumes are present.
 

State of California Proposition 65 Warnings

WARNING: This product contains one or more chemicals 
known to the state of California to cause cancer.
WARNING: This product contains one or more chemicals known to the 
state of California to cause birth defects or other reproductive harm.

Intended Use

Do NOT modify this unit in any way or adapt it for any other use.  
Modification of this unit in any way will void all warranties and could 
create safety hazards.

Your new Powr-Flite unit is a high quality, precision-made product.  All parts used in the 
manufacturing of this unit have passed rigid quality control standards prior to assembly.  Please 
safeguard the original receipt/invoice given at the time of purchase.  If you experience any 
problems with your unit during the warranty period, the original receipt/invoice will act as proof of 
purchase.
Upon receipt, inspect outer box for exterior damage. Unpack all internal parts, ensure all items 
are present according to the owner’s manual, and review components for damage.
Each unit is tested and thoroughly inspected prior to shipping.  If damage is discovered, 
immediately notify the transportation company that delivered your machine and request an 
inspection. As a manufacturer, we are unable to act upon any claim for concealed damage and 
you must originate the claim.  Be sure to keep the carton, packing inserts, and carrier’s receipt 
until the inspector has verified your claim.

Summary of Contents for PE060-G15-U

Page 1: ...Pulsar Extractor OPERATOR S MANUAL PE060 G15 U ...

Page 2: ...2 CONTENTS Introduction 3 Warranty 3 Grounding Instructions 4 Important Safety Instructions 5 General Instructions 6 Maintenance 7 Storage of Equipment 8 Troubleshooting Information 9 ...

Page 3: ...pt it for any other use Modification of this unit in any way will void all warranties and could create safety hazards Your new Powr Flite unit is a high quality precision made product All parts used in the manufacturing of this unit have passed rigid quality control standards prior to assembly Please safeguard the original receipt invoice given at the time of purchase If you experience any problem...

Page 4: ... codes and ordinances This appliance is for use on a nominal 115 volt circuit and has a grounding plug that looks like the plug illustrated in sketch A A DANGER Improper use of the grounding plug can result in a risk of electric shock WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you a...

Page 5: ...e with any opening blocked keep free of dust lint hair or anything that may reduce air flow 7 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 8 DO NOT pick up anything that is smoking or burning such as cigarettes matches or hot ashes 9 DO NOT use to pick up hazardous chemicals 10 Turn off all controls before unplugging 11 Turn unit off immediately if foa...

Page 6: ...amp wall socket circuit 4 Attach the hose system to the unit and to your carpet wand 5 Turn the pump switch 1 Fig 3 to the ON position 6 Turn the vacuum switch 2 Fig 3 to the ON position to begin cleaning 7 When recovery tank is full empty by using drain hose on the front of machine If a pail is used to empty the recovery tank do not use the same pail to fill the solution tank as this can result i...

Page 7: ... use with clear clean water A white vinegar solution may also be used This will counter act hard water and alkaline deposits and aid in keeping orifices clean 4 Do not allow fluid either in solution or recovery tank to sit overnight The unit should be emptied and cleaned daily 5 Clean the strainer in the solution tank Fig 4 daily 6 Do not use the same receptacle pail to fill solution tank that has...

Page 8: ...ss instructions to perform it by an authorized shop are obtained from the factory 3 Do not use citrus based D Limonene cleaners in this machine 4 Do not use cleaning chemicals in this machine except those recommended for steam type extraction equipment The use of any chemicals with abrasive additives voids the warranty 5 Do not use any replacement parts except those specified on the parts list Per...

Page 9: ...ank lid 5 Loose hose connection 6 Vacuum motor exhaust blocked 1 Close drain hose 2 Repair or replace hose 3 Open machine connect vacuum hose to recovery tank 4 Replace tank lid Recovery tank lid must be closed 5 Check for leaks around clamps and cuffs vacuum motor Replace damaged hose s 6 Check air flow by removing hose from machine and feel the exhaust under the machine Remove obstruction Motor ...

Page 10: ...ution tank 2 Clogged jet 1 Unscrew strainer and remove lint and any other foreign material from screen 2 Remove and clean Leaking or stuck solution valve 1 Foreign material in valve 2 Loose brass hex nut 3 Valve or seals worn 1 Remove brass hex plug clean valve and replace 2 Reseal hex and plug 3 Replace worn parts with solution valve repair kit Pump motor not working 1 Loose wiring 2 Defective pu...

Page 11: ...11 NOTES ...

Page 12: ...12 Powr Flite 3101 Wichita Court Ft Worth TX 76140 1755 Phone 817 551 0700 WWW POWR FLITE COM P OMPE060 G15 U 08 2021 Record of Purchase Serial Number Purchase Date Dealer Phone Number ...