Maximum Power Current Imp [A] :
7.31
7.43
7.55
7.67
7.81
7.95
Maximum Power Voltage Vmp [V] :
29.4
29.6
29.8
30.0
30.1
30.2
Over-current protection rating [A]:
12
Application Class (IEC 61730) :
Class A / B / C
Protection Class :
Class II
(a)The above electrical characteristics are based on the results of on going tests. Please do not expose solar
modules to sunlight concentrated with mirrors, lenses or similar means. Under normal conditions, a
photovoltaic module may experience conditions that produce more current and /or voltage than reported at
Standard Test Conditions. Accordingly, the values of Isc and Voc marked on CE listed modules should be
multiplied by a factor of 1.25 when determining component voltage ratings, conductor capacities, fuse sizes
and size of controls connected to the module output.
(b)Class A: Hazardous voltage (IEC 61730: higher than 50V DC; EN 61730: higher than 120V), Hazardous
power applications (higher than 240W) where general contact access is anticipated (Modules qualified for
safety through EN IEC 61730-1 and -2 within this application class are considered to meet the requirements
for Safety Class
Ⅱ
).
Modules rated for use in this application class, may be used in systems operating at greater than 50V DC or
240W, where general contact access is anticipated. Modules qualified for safety through this part of
IEC61730 and IEC61730-2 and within this application class are considered to meet the requirements for
safety class
Ⅱ
.
Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current
and/or voltage than reported at standard test conditions. Accordingly, the value of Isc and Voc marked on
this module should be multiplied by of 1.25 when determining component voltage ratings, conductor current
ratings, fuse sizes, and size of controls connected to the PV output.
Artificially concentrated sunlight shall not be directed on the module.
1.The rules of preventing fire is dependent on the location.
2.The mounting design may have an impact on the fire resistance.
3.The recommended stand-off height is about 115 mm, If other mounting means are employed, this may
affect the Listing For Fire Class Ratings.
Type Name or Model No. :
PWxxxS2-36 (xxx=135, 140, 145, 150, 155, 160,165)
Rated Maximum Power [W] :
135
140
145
150
155
160
165
Maximum System Voltage [VDC] :
1000
Tolerance of Rating :
0~+6W
Rated Short Circuit Current Isc [A] :
8.20
8.42
8.57
8.82
9.07
9.15
9.55
Rated Open Circuit Voltage Voc [V] :
21.9
22.1
22.3
22.4
22.6
22.7
22.8
Maximum Power Current Imp [A] :
7.59
7.78
7.92
8.15
8.38
8.51
8.82
Maximum Power Voltage Vmp [V] :
17.8
18.0
18.3
18.4
18.5
18.6
18.7
Over-current protection rating [A]:
12
Application Class (IEC 61730) :
Class A / B / C
Protection Class :
Class II