PROBLEM OR CONCERN POSSIBLE CAUSE
SOLUTION
Gun/Hose - Leaking water
Gun/Hose will need to be replaced. Replace-
ment parts are not available
f
or the Gun/Hose.
Email us at
:
f
or assistance or order online at
:
www.hdpowerwasher.com.
Leaking
O
il
f
rom Pump
A small amount o
f
leakage is
normal
I
f
leakage occurs please contact us directly at
Leaking water
f
rom bottom
o
f
unit
Machine Inlet connection is de-
f
ective
Check the Machine Inlet at the
f
ront o
f
the unit to
ensure that water is not leaking
f
rom it. I
f
the con-
nection is leaking it will have to be replaced.
Contact us at
or order a replacement directly online at
www.hdpowerwasher.com
.
Pump housing is leaking water
Email us at
f
or assistance.
Low pressure
Faucet not
f
ully open or unit is not
receiving a
f
ull volume o
f
water
O
pen the
f
aucet all the way.
Not building maximum Pressure Screen Filter is clogged
Clean the Screen
f
ilter as instructed in the section
5
.4.
Irregular Pressure
Gun or Hose
f
ailure
Replace Gun and/or Hose. Contact us at
or order online at
www.hdpowerwasher.com
.
Kink in the Garden Hose or Hose
is wrapped on a storage wheel
Unwrap the Garden Hose and lay it out
f
lat to
ensure that there are no kinks in the Hose.
Water leaking
f
rom either Hose
or Unit
Stop water
f
rom leaking be
f
ore using the unit or
contact us i
f
you need assistance.
Garden Hose length is too long Shorten the length o
f
the Garden Hose. We recom-
mend a maximum length o
f
25
to
50
f
eet
f
or City
water supply and
30
f
eet
f
or Well water supply.
Clogged Nozzle
Clean the Nozzle as instructed in section
5
.
2
.
Air in Pump
Let Pressure washer run with Gun trigger de-
pressed and Wand removed until a steady
stream o
f
water is released.
No Wand attached to the
f
ront
o
f
the Gun
Attach wand. (High pressure is created in the
wand and not the gun)
No water coming out o
f
Wand
Clogged Nozzle
Clean Nozzle as instructed in section
5
.
2
.
Q
uick Connect is attached in-
correctly
See section
3
.
2
. To Attach
Q
uick Connect pro-
perly, keep the outer collar o
f
the
Q
uick Con-
nect held back while sliding the
Q
uick Connect
all the way
f
orward against the Inlet Nipple and
then release the collar to lock it into place. (The
collar is spring loaded so i
f
it is released too
soon it will not lock into place).
Sceen Filter is clogged
Clean the Sceen
f
ilter as instructed in section
5
.4.