6 INSTRUCTIONS PW220/PW230
1.3.8 PEL-1 Electric Latch and PS-1 Stopper
Table 6: List of small parts for PEL-1 and PS-1
Quantity
M8*25L hex bolt
3pcs
M8 self-locking nut
3pcs
Key
2pcs
2. Installation:
2.1 Notes of Motors in Operation
The PW220/PW230 gate openers are applicable to per leaf of 2.5/3.5 meters in width and 200/300 kg in weight which can be opened up
to 110 degrees primarily for residential use; where the performance shall be influenced by the factors such as gate dimension, weight and
climate that the driven torque is necessarily to be adjusted properly.
2.1.1 Tools in Installing
Please make sure all tools and cables are ready and conform to the industrial safety standard before installation. Please refer to
Figure 11.
Figure 11
Figure 10
PEL-1 electric latch is used to lock the gate and it has to be
used with PS-1 stopper and installed on the master gate.