INSTRUCTIONS PW220/PW230 11
10. Refer to
Figure 23
, the distance between front plate of
the motor and rear plate is 735mm (PW220) / 798mm
(PW230), the difference in height is 18.3mm (PW220) /
22.5mm (PW230).
Figure 23
(1)
PW220
(2)
PW230
11. Clamp and fix the motor front plate on the door
temporarily.
Figure 24
(1)
PW220
(2)
PW230
12. Lift up the motor and insert the screws into the front
plate.
13. Lift the motor overhead and push the gate to the end until the
screw holes of the motor end matches the holes on the rear plate.
Fasten the motor to the rear plate with the bolt as shown in
Figure25
.
Figure 25
14. Fasten the nut tightly and loosen it for half round for
motor supporting in rotating.
15. Fasten the motor front end to the front plate with the bolt (A)
and nut (B) tightly. Fully tighten the screw.
Figure 26
(1)
PW220
(2)
PW230
16. Use appropriate release key to release the gear motor.
17. Try to push the released gate and make sure the motor can be
manually moved easily.
18. Make sure the motor front plate can be fastened on the gate
to be installed permanently.
19. Use the appropriate release key to fasten the gear motor
again.
20. Loosen the plastic nut under the power cable of the motor
end, and penetrate the power cable through the nut and screw
it up.
21. Connect the motor power cable as shown in
Figure 27
.
Figure 27
22. Close the gear motor cover by tightening the two screws
as shown in
Figure28
.
Figure 28
Summary of Contents for PW220