background image

INSTRUCTIONS PW150/PW200

2

1) Warnings

Please read this instruction manual carefully before the  

installation of gate-automated system.

This manual is exclusively for qualified installation 

personnel. Powertech Electronics Inc. is not responsible for 

improper installation and failure to comply with local 

electrical and building regulations.

Keep all the components of PW150/PW200 system and this 

manual for further consultation.

In this manual, please pay extra attention to the contents 

marked by the symbol:

Be aware of the hazards that may exist in the procedures 

of installation and operation of the gate-automated 

system. Besides, the installation must be carried out in 

conformity with local standards and regulations.

If the system is correctly installed and used following all 

the standards and regulations, it will ensure a high degree 

of safety.

Make sure that the gates works properly before installing 

the gate-automated system and confirm the gates are 

appropriate for the application.

Do not let children operate or play with the 

gate-automated system.

Do not cross the path of the gate-automated system when 

operating.

Please keep all the control devices and any other pulse 

generator away from children to avoid the gate-automated 

system being activated accidentally.

Do not make any modifications to any components except 

that it is mentioned in this manual.

Do not try to manually open or close the gates before you 

release the gear motor.

If there is a failure that cannot be solved and is not 

mentioned in this manual, please contact qualified 

installation personnel.

Do not use the gate-automated system before all the 

procedures and instructions have been carried out and  

thoroughly read.

Test the gate-automated system weekly and have 

qualified installation personnel to check and maintain the 

system at least every 6-month.

Install warning signs (if necessary) on the both sides of 

the gate to warn the people in the area of potential 

hazards.

Summary of Contents for PW150

Page 1: ...SWING GATE OPENERS FOR RESIDENTIAL USER MANUAL 24V DC GEAR MOTOR Flashing Light Control box Push Button Gate 2 Gate 1 ...

Page 2: ......

Page 3: ... and Its Installation in Illustration 3 2 Power Connection 3 2 1 Notes for Power Connection 3 3 Installation 3 3 1 Preparation for Motor Installation 3 3 2 Installation of The Gear Motors 3 3 3 PKS 1 Key Selector 3 3 4 PPB 1 Push Button 3 3 5 PF 1 Flashing Light 3 3 6 PH 1 Photocells 3 3 7 PEL 1 Electric Latch and PS 1 Stopper 4 Technical Characteristics 4 1 PW150 4 2 PW200 4 3 PH 1 Photocells 4 4...

Page 4: ...orks properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accidentally Do...

Page 5: ...cessories of a gate automation system 2 3 Description of Devices A B C D E PW150 PW200 includes the accessories shown in Figure 2 Please check the accessories the same as the package provided Attention Some accessories of PW150 PW200 are not included due to local regulations or customized order A 2 PW150 PW200 electromechanical gear motors B Mounting brackets C 1 pair of PH 1photocells one TX and ...

Page 6: ... 6 2 3 3 PH 1 Photocells The pair of PH 1 photocells has to be installed on the wall and connected to the control panel The function of the photocells is to detect the obstacles found on the optical axis between the transmitter TX and the receiver RX 2 3 4 PR 1 Radio Transmitter In dual gate installation Press the button A on the transmitter for dual gate operation Press the buttom B on the transm...

Page 7: ...er PKS 1 key selector is supplied with two keys 2 3 7 PPB 1 Push Button The PPB 1 push button is used for opening the gate indoors without the radio transmitter 3 1 Notes of Motors in Operation The PW150 PW200 gate openers are applicable to per leaf of 2 2 5 meters in width and 150 200 kg in weight which can be opened up to 110 degrees primarily for residential use where the performance shall be i...

Page 8: ...200 requires very low voltage that no professionally trained personnel is required in installation however the users are advised to read the installation manual carefully before going for it After getting to know all accessories and their positions suggest starting from cable conduit arrangement to prevent the cables from being broken or damaged 3 2 Power Connection 1 The installation of power sup...

Page 9: ...rce regulations 3 Make sure there is no serious friction existing in the opening or closing travel of the gate leaves 4 Make sure the gate is at horizontal level that the gate will not move aside at any position 5 Make sure the gate can bear the impact of the motor torque when it is installed on any hole of the bracket which the surface is sufficiently sturdy 6 Make sure the photo sensors are inst...

Page 10: ...h the leaves opening angle of 100 degrees then the value of B is approximate 190mm Please make sure B and A are similar or the same in value that the leaves can be operated smoothly also to reduce the burden of the motor 9 If the gate is OPENED OUTWARD please leave at least 70mm between the post brackets and the gate Min 70mm Min 70mm PW150 PW200 PW150 PW200 150 160 170 180 190 150 160 170 180 190...

Page 11: ... 17 place the rear plate in the correct position on the mounting surface Inspect if the distance is proper as shown in Figure 22 i e the position the front plate of the motor to be installed 7 Place two post brackets on the surface to be installed and mark the drilling points then drill minimum diameter of 8mm holes by four on the mounting surface to be installed and fasten up the brackets with sc...

Page 12: ...o push the released gate and make sure the motor can be manually moved easily 17 Make sure the motor front plate can be fastened on the gate to be installed permanently 18 Use the appropriate release key to fasten the gear motor again 19 Loosen the plastic nut under the power cable of the motor end and penetrate the power cable through the nut and screw it up 20 Connect the motor power cable as sh...

Page 13: ...the three holes at the bottom and mark the points by the holes as reference 6 Drill the holes in the wall and fix the bottom to the wall by three screws See Figure 3 3 3 5 7 Connect the electric wires to the terminals as shown in Figure 3 3 3 6 and it s not required to distinguish any polarity The terminals can be removed for connecting the wires easily 8 Turn the key and insert the shell on the b...

Page 14: ...ght of about 100cm so that it could be used by most people 2 Remove the round cover A by prizing it out with a screwdriver See Figure 3 3 4 1 3 Unscrew the two screws beside the button 4 Separate the upper shell with the bottom See Figure 3 3 4 2 5 Breach the three holes at the bottom and mark the points by the holes as reference 6 Drill the holes in the wall and fix the bottom to the wall by thre...

Page 15: ...ry See Figure 3 3 5 5 6 Tighten the four screws back on the light base Figure 3 3 5 6 7 Replacing the bulb set See Figure 3 3 5 7 7 1 Unscrew the flashing light wires from the PCB terminals and make sure the power of the light is off 7 2 Release the three screws A B C of the flashing light cover 7 3 Separate the flashing light cover and replace the bulb set with a new one 7 4 Tighten the three scr...

Page 16: ...ttach the stopper to the ground with screws and washers See Figure 3 3 7 3 3 Wiring connection TX Connect the 1 and 2 terminals on the transmitter with the terminals GND and 24V on the PL600 1000 PCB RX Connect the 1 2 and NC terminals on the receiver with the terminals GND 24V and PH1 on the PCB600 1000 PCB See Figure 3 3 6 4 Figure 3 3 6 5 Figure 3 3 6 4 Figure 3 3 6 5 CA CC NA Normal Open NC No...

Page 17: ... 7 7 2 Weld the back plate of the electric latch to the surface on the master gate See Figure 3 3 7 8 Please avoid melting the wires by the heat of the fixed plate Figure3 3 7 4 Unscrew the screws Figure3 3 7 7 Change the spring and screw it in the different place Figure3 3 7 8 For the gate opened inward Figure3 3 7 9 For the gate opened Outward Installation Figure3 3 7 5 Take the casing off Figur...

Page 18: ...Worm gear 1500N 360mm 24Vdc 4 2A for maximum 10 seconds 150 kg per leaf 2 meters 20 20 50 674mm 98mm 170mm 3 1kg 24Vdc motor with mechanical release Worm gear 2000N 400mm 24Vdc 4 2A for maximum 10 seconds 200 kg per leaf 2 5 meters 20 20 50 799mm 98mm 170mm 3 6kg PW150 PW200 4 3 PH 1 Photocells Detection type Operating distance Response time Input voltage Operating Temperature Protection class Dim...

Page 19: ...te operation 3V with one CR2032 button type lithium battery 20 50 71 5mm 33mm 14mm 4 8 PEL 1 Electric Latch Application Power Supply Operating Temperature Operating Current Dimension For locking the gate 24Vdc 20 50 5A 61mm 55mm 120mm 4 6 PF 1 Flashing Light Application Lamp Operating Temperature Installation Dimension For warning purpose during leaves movement 24Vdc Halogens bulb 20 50 horizontal...

Page 20: ...e of the above product has been tasted for CE marking according to the following European Directives 2006 42 EC Machinery Directive Comply with the following Standards EN 301489 1 V1 8 1 2008 EN 301489 3 V1 4 1 2002 EN 300220 1 V2 1 1 2006 EN 300220 2 V2 1 2 2007 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 103 2003 EN 62233 2008 EN 12445 2001 EN 12453 2001 And also declar...