GARAGE DOOR OPENERS USER MANUAL
11
4.7 Programmable function setting
LED Display
Definition
Function
Value
Description
Deceleration position starting
point(% full operation)
Open/Stop/Close/Stop
function key
LED light function key
Extra-device function key
Photocell function mode
Warning Buzzer
Auto-close adjustment
LED light function
Over current reaction mode
Over current setting
1
2
3
4
5
6
7
8
9
A
1-1
1-2
1-3
1-4
1-5
2-0
2-1
2-2
2-3
2-4
3-0
3-1
3-2
3-3
3-4
4-0
4-1
4-2
4-3
4-4
5-0
5-1
5-2
6-1
6-2
7-1
7-2
7-3
7-4
7-5
7-6
7-7
7-8
7-9
8-1
8-2
8-3
8-4
9-1
9-2
9-3
1-0
2-0
3-0
4-0
5-0
6-0
7-0
8-0
9-0
9-9
75%
80%
85%
90%
95%
Function off
A Key
B Key
C Key
D Key
Function off
A Key
B Key
C Key
D Key
Function off
A Key
B Key
C Key
D Key
Function off
Stop when photocell is activated
Opening phase: Keep opening when activated
Closing phase: Stop when activated.
Function off
Function on
Function off
30 sec
60 sec
90 sec
120 sec
150 sec
180 sec
210 sec
240 sec
Function off
LED light start running 1 minute
LED light start running 2 minutes
LED light start running 3 minutes
Stop when over current occur
Opening phase: Stop when over current
Closing phase: Reverse 10 cm when over current
Reverse to the end when over current.
Learning current add 0.2A as over current
Learning current add 0.4A as over current
Learning current add 0.5A as over current
Learning current add 0.6A as over current
Learning current add 0.8A as over current
Learning current add 1.0A as over current
Learning current add 1.2A as over current
Learning current add 1.4A as over current
Learning current add 1.6A as over current
Learning current add 1.8A as over current
1.The factory setting is "1-3"
2. The door will reverse 2cm if over current occur in
last 10% distance.
1.The factory setting is "2-1"
1.The factory setting is "3-2"
1.The factory setting is "4-3"
1.The factory setting is "5-0 "
1.The factory setting is "6-1"
2. IF the door left opened for longer than 10mins then buzzer
start beeping and turn off until the door been closed.
1.The factory setting is "7-1"
1.The factory setting is "8-4"
1.The factory setting is "9-2"
1. The factory setting is "3-0"