12. Firmware Update Procedure
In order to update the Firmware, download the latest
version of the Firmware Updater on the Powersoft
Website. (RESTRICTED AREA > SERVICE CENTRE AMP
MODULES > MDRIVE TOOLS)
Contact the Powersoft Service in order to obtain the
latest firmware version.
Install the RS485 driver.
Connect the DPC Interface to the module.
Connect the module to the PC by means of the PC000096
adapter and the CB000214 cable.
Set the ID to 9.9.
Run the Firmware Updater (v1.1.40 onward).
Select “Update MDrive Firmware”. (Fig. 38)
WARNING: DO NOT DISCONNECT THE
MODULE WHILST TESTING!!!
M-DRIVE
PC
DPC INT
RS485
KT000193
Interface
M-DRIVE
Pressure
Sensor
SET 9.9
RS485
PC
PC000096
CB000214