background image

Defender 650/1200/1600's have a user replaceable battery feature. Please read 
warning on the front page about battery safety and follow the steps carefully shown 
below. Please use only PowerShield approved battery pack to maximize the perfor-
mance of the unit.

1. Shutdown all connected equipment and turn the UPS off by pressing on / off  
    button.
2. Remove input cord from mains and remove all output cords from the UPS.
3. Flip the UPS upside down. 
    For Defender 1200/1600, locate the Philips head screw on the bottom of the front 
    panel. Remove the screw using a Philips screw driver.

    For Defender 650, locate the two slots on the bottom of the front panel. Insert a 
    flat head screw driver in one of the two slots. Press gently down towards front  
    while also gently levering the screw driver towards front. Repeat for the second 
    slot to unclip front panel.
4. Remove the front panel by grabbing the bottom edge of the front panel and pull 
    forward. Please be careful not to apply excess force to the panel as it may 
    cause damage to the LCD cable attached to it.
5. Remove the metal plate holding the battery pack in the enclosure by sliding it 
    upwards and then pull out.
6. Pull tag of the battery pack and remove the battery from the unit
7. Remove Red (Positive) and Black (Negative) battery wires from the battery pack.
8. Prepare new battery pack. Connect Black (Negative) wire to the new battery 
    black terminal and connect Red (Positive) battery wire to the red battery terminal. 
    Note:You will see a small spark when you connect red wire to the battery. This is 
    normal as the unit charges some components. Please check polarity of battery 
    terminals.
9. Insert the battery back into the unit and put the metal plate back in to the front of 
    the enclosure. Replace the front panel. For Defender 1200/1600, fasten the 
    Philips screw.
10. Please recharge the unit for 6 hours before you turn the unit on.

Please follow the trouble shooting section below. If the problem cannot be
resolved, please check PowerShield FAQ web page or call our customer support
for further assistance.

Summary of Contents for defender PSD 650

Page 1: ...lated equipment such as medical equipment life support system microwave oven and vaccum cleaners Also since this unit output is not sinusoidal please do not connect AC line filters motors and other in...

Page 2: ...tteries 1 Remove watches rings and other metal objects 2 Use proper tools with insulated handles 3 Do not lay tools or metal parts on the top of batteries 4 Disconnect charging source prior to connect...

Page 3: ...Connect peripherals that do NOT need battery backup Connect USB cable and computer Install NetGuard UPS monitoring software for advanced power monitoring Breaker will trip when there is overload short...

Page 4: ...oring software from www powershield com au index php downloads 2 When the installation is completed NetGuard agent icon will appear on the Task bar 3 Once installation is completed click the plug icon...

Page 5: ...pull forward Please be careful not to apply excess force to the panel as it may cause damage to the LCD cable attached to it 5 Remove the metal plate holding the battery pack in the enclosure by slidi...

Page 6: ...rtation costs to ship the replacement to the customer within Australian capital cities metro areas only 1 Review the problems discussed in the troubleshoot section of this manual to eliminate common p...

Page 7: ...rge Protection 2 3 Surge Protection 0 3 BATTERY Battery Type Number 12V 9AH x1 12V 7AH x2 12V 9AH x2 Backup Time One PC Load 120W 25min 40min 45min Typical Recharge Time 4 6 Hours recover to 90 capaci...

Reviews: