background image

4 - ENG

OPERATING INSTRUCTIONS

TYPICAL INSTALLATION

To begin using the tool:

1. 

As a standard practice, drain water from the air        

Figure 2

L 3/8” Square drive

P Air inlet port

M Forward/Reverse button

Q Male connector

N Speed control screw

R Exhaust port

O Trigger 

S Teflon tape

 

 

compressor tank and air lines prior to use each day  

 

(reference your compressor operators manual for    

 

detailed instructions).

2. 

Install a 1/4” NPT male connector (not included) into  

 

the air inlet port on the tool (see Figure 2). 

Note:    

 

Use Teflon® Tape on all threaded connections.

3. 

Turn on the air compressor and allow it to build up   

 pressure.

4. 

Adjust the air compressor’s regulator or the supply   

 

line regulator to 90 PSI.

 

5. 

Attach the desired 3/8” square drive socket (use 3/8” deep sockets and only use extensions when  

 

needed).  

 

Always use impact-type sockets and extensions that are designed for ratchet 

 

 

  wrenches. Hand tool sockets will shatter and potentially cause personal injury and/or  

 

 

  property damage.

6.   Connect the tool to the air hose quick coupler. 

NOTE: It is recommended that a whip hose with a swivel  

 

(P012-0079SP - not included) be used to prevent twisting, kinking and excessive wear to the air hose  

 

(ref. item “F” in figure 1 for recommended connections).

Always grip the air ratchet well to avoid the chance of it being wrenched from your  

 

 

  grasp or the possibility of it throwing you off balance. 

7. 

Select the tool rotation direction. Push in and turn the forward/reverse button to the right (clockwise) for  

 

forward or the left (counterclockwise) for reverse.

 a. 

To remove a fastener, push in and turn the forward/reverse button to “R” (counterclockwise). Grip the  

 

 

wrench with your hand and place it on the fastener to be loosened. Break the fastener loose by hand,  

 

 

then gently squeeze the trigger to completely remove it. Release the trigger to stop the tool. 

  

NOTE: Soak rusted nuts in penetrating oil and break the rust seal before removing with the air  

 

 

ratchet wrench. If the nut does not start to move in three to five seconds, use a larger size air  

 

 

ratchet wrench. Do not use the air ratchet wrench beyond the rated capacity, as this will 

 

 

drastically reduce the tool life.

 

b. 

To tighten a fastener, push in and turn the forward/reverse button to “F” (clockwise). Start the  

 

 

fastener by hand then grip the ratchet wrench with your hand and place it on the fastener to be  

 

 

tightened. Gently squeeze the trigger to tighten down the fastener. Drive the fastener until the ratchet  

 

 

stalls, release the trigger to stop the tool, and then tighten further by operating the air ratchet wrench in  

 

 

the same manner as you would operate a manually operated ratchet wrench.

 

c.   To adjust the speed of the tool, turn the speed control screw to the left (counterclockwise) to decrease  

Key

Description

Key

Description

Key

Description

Key

Description

A Air hose

D In-line Oiler

G Quick Coupler

J Female Connector

B In-line Filter

E Air Hose 

H Male Connector

K Spray Gun

C Tee Fitting

F Whip Hose 

I Air Tool

Figure 1

Summary of Contents for PX P024-0303SP

Page 1: ...es de seguridad contenidas en este manual antes de utilizar esta unidad Si no cumple con las instrucciones de este manual podr a ocasionar lesiones personales da os a la propiedad y o la anulaci n de...

Page 2: ...ss of control of the tool PERSONAL SAFETY RISK OF INJURY Stay alert Watch what you are doing and use common sense when operating the tool Do not use the tool while tired or under the influence of drug...

Page 3: ...K OF BURSTING AND OR INJURY Check for misalignment or binding of moving parts breakage of parts and any other condition that affects the tool s operation If damaged have the tool serviced before using...

Page 4: ...ct the tool rotation direction Push in and turn the forward reverse button to the right clockwise for forward or the left counterclockwise for reverse a To remove a fastener push in and turn the forwa...

Page 5: ...o the air supply cover the exhaust port end with a towel and run in forward and reverse directions for approximately 30 seconds Follow the air motor lubrication instructions above after cleaning is co...

Page 6: ...liable for any repairs replacements or adjustments to the equipment or any costs for labor performed by the purchaser without the Company s prior written approval The effects of corrosion erosion and...

Page 7: ...on ce que vous faites et faites preuve de bon sens lorsque vous utilisez l outil N utilisez pas l outil lorsque vous tes fatigu en tat d bri t intoxiqu par une drogue ou lorsque vous avez pris des m d...

Page 8: ...NT ET OU DE BLESSURE V rifiez l alignement et le d gagement des pi ces mobiles l tat des pi ces et toute autre condition pouvant influer sur le fonc tionnement de l outil Si un outil est endommag fait...

Page 9: ...ment pivot P012 0079SP non inclus afin d emp cher le tuyau flexible de s entortiller ou de se plier et de pr venir son usage excessif voir l l ment F de la Figure 1 pour les connexions recommand es Te...

Page 10: ...tionner l outil dans les deux sens de rotation pendant environ 30 secondes Apr s le nettoyage suivez les directives de lubrification du moteur pneumatique ci dessus pour lubrifier l outil nouveau Apr...

Page 11: ...des r parations remplacements ou r glages du mat riel ou des co ts de main d oeuvre de l acheteur sans le consentement pr alable par crit de la Soci t Les effets de la corrosion de l rosion et de l us...

Page 12: ...utilice el sentido com n mientras utiliza la herramienta No utilice la herramienta si est cansado o bajo los efectos de f rmacos alcohol o medicamentos Un momento de distracci n mientras utiliza la h...

Page 13: ...ramienta es peligrosa en manos de usuarios sin capacitaci n RIESGO DE ESTALLAR Y O DE LESI N Verifique que no haya partes movibles mal alineadas o atascadas partes rotas y cualquier otra condici n que...

Page 14: ...ue la manguera de aire se doble enrosque o gaste demasiado ver tem F en la figura 1 para las conexiones recomendadas Sujete siempre el trinquete neum tico con firmeza para evitar que se le escape o le...

Page 15: ...te alrededor de 30 segundos Siga las instrucciones de lubricaci n de motores de aire m s arriba luego de finalizar la limpieza para lubricar nuevamente la herramienta Luego de engrasar o limpiar cubra...

Page 16: ...zo bajo esta garant a deben ser pagados por el comprador minorista original Este es el nico recurso posible bajo esta garant a Si el comprador minorista original no instala mantiene u opera dicho equi...

Reviews: