DETAIL A
1. Refer to the Loading Chart, in this Manual or on the face of the LiftGate Unit, to
determine if the load to be lifted will fit in the load capacity envelope of the Unit.
2. The Rocker Switch controls the up/down operation of the unit. Depressing the
top of the switch will raise the toeplate and depressing the bottom of the switch
will lower the toeplate. Raise the toeplate off the surface and dis-engage the
Lock Pin, to allow positioning of the Unit. Manuever the toeplate to the load and
lower the toeplate to the surface. Place load on the toeplate and secure the
load to the Unit using the strap provided.
3. Raise the load to the desired height. The actuator will make a ratcheting sound
when the top stroke limit is reached.
4. Swing the load to required position using the Unit Handles. Use the Lock Pin
whenever possible.
5. Lower the load down to the desired surface(vehicle floor or the ground). The
down stroke will end automaticly when the toeplate makes contact with any
surface. Remove the load.
6.
When the operation is complete, park the Unit folded in the vehicle. Engage the
lock pin, lower the toeplate to the floor until the actuator stops(automatic), and
depress the Emergency Stop/Battery Disconnect Switch.
WARNING! The vehicle must be parked on a level surface prior to operating the
LiftGate Unit. Safety shoes must be worn! Read the instructions completely
before operating the unit. DO NOT exceed Max. Capacity Limit.
PowerMate
®
LiftGate™
Installation & Operation Manual
OPERATING INSTRUCTIONS
A
PN 018330 Rev.D2
Eng. 01/ 10/ 13
Lock Pin
Main Swing Arm
Top Handle
Bottom Handle
Actuator
Control Box
Fuse Holder
with 30A Fuse
Emergency Stop/
Battery Disconnect
Switch
Rocker Switch
3.01