To avoid personal injury, always shut off and 

unplug the compressor and relieve all air pressure from 
the system before performing any service on the air 
compressor.

Regular maintenance will ensure trouble free operation.

Your electric powered air compressor represents high quality
engineering and construction; however, even high quality
machinery requires periodic maintenance. The items listed
below should be inspected on a regular basis.

Condensation will accumulate in the

tank. To prevent corrosion of the tank from the inside, 
this moisture must be drained at the end of every 
workday. Be sure to wear protective eyewear. Relieve
the air pressure in the system.  Tip the compressor (if 
necessary for your model) so the petcock is at the 
bottom of the tank(s). Then open the petcock to allow 
moisture to drain from the tank (See B and D) on 
pages 12, 13 and 14.

NOTE:

In cold climates, drain the tank after each use to 
reduce problems with freezing of water 
condensation.

A dirty air filter will reduce the compressor’s performance

and life. To avoid any internal contamination of the pump, the
filter should be cleaned frequently and replaced on a regular
basis (see A). Foam filters should be cleaned in warm, soapy
water. Do not allow the filter to become filled with dirt or paint.
Direct exposure to dirty conditions or painting areas will void
your warranty.

Pour éviter les risques de 

blessures, arrêtez et débranchez toujours le compresseur 
et libérez toute la pression d'air dans le circuit avant 
de procéder à l'entretien.

L'entretien régulier de l'appareil permettra d'assurer un

fonctionnement sans problèmes. Votre compresseur d'air
électrique est un appareil de haute qualité ; toutefois, même les
machines de haute qualité nécessitent un entretien périodique.
Les composants énumérés ci-dessous doivent être inspectés
réqulièrement.

De la condensation se 

forme dans le réservoir. Pour éviter la formation de 
corrosion depuis l'intérieur du réservoir, cette 
condensation doit être évacuée à la fin de chaque 
journée de travail. Veillez à porter des lunettes de 
protection. Libérez la pression d'air dans le circuit et 
ouvrez le robinet de purge en bas du réservoir pour 
vidanger. Incliner légèrement le compresseur (si cela 
est nécessaire pour votre modèle) afin que le robinet 
soit en bas du/des réservoirs. Ouvrez le robinet  pour 
purger toute l’humidité accumulée dans le réservoir 
(Voir B et D) aux pages 12, 13 et 14.

REMARQUE :

Dans les climats froids, purger le réservoir

après chaque utilisation afin de réduire les problèmes de gel
d'eau de condensation.

Un filtre à air sale nuit aux performances et à la durabilité du

compresseur. Pour éviter de contaminer l'intérieur de la pompe,
nettoyer le filtre fréquemment et le remplacer régulièrement (voir
A). Nettoyer les filtres en mousse à l'eau tiède savonneuse. Ne pas
laisser de saletés ou de peinture obstruer le filtre. L'exposition
directe à des conditions poussiéreuses ou à une aire de peinture
annulera votre garantie.

Para evitar lesiones personales, 

siempre apague y desenchufe el compresor y alivie toda la 
presión de aire del sistema antes de realizar algún tipo de 
servicio en el compresor de aire.

El mantenimiento regular asegurará una operación sin

problemas. Su compresor de aire con alimentación eléctrica
representa lo mejor en ingeniería y construcción; sin embargo, aún
la maquinaria de mejor calidad requiere un mantenimiento
periódico. Los elementos enumerados a continuación deben
inspeccionarse de manera regular.

La condensación se acumulará 

en el tanque. Para evitar la corrosión del tanque desde el 
interior, esta humedad debe ser drenada al final de cada 
día de trabajo. Asegúrese de utilizar protección ocular. 
Alivie la presión de aire en el sistema y abra la llave de 
descompresión que se encuentra en el fondo del tanque 
para drenar. Incline el compresor (si es necesario en 
caso de su modelo) para que el grifo de desagüe quede 
en el fondo del tanque o tanques. Luego abra el grifo de 
desagüe para permitir que el agua de la humedad 
drene del tanque. (Vea B y D) en las páginas 12, 13 y 14.

NOTA:

En climas fríos, drene el tanque después de cada uso

a fin de reducir los problemas por el congelamiento del agua de
condensación.

Un filtro de aire sucio reducirá el rendimiento y la vida del

compresor. Para evitar la contaminación interna de la bomba, el
filtro se debe limpiar con frecuencia y reemplazar regularmente
(vea A). Los filtros de espuma se deben limpiar en agua jabonosa
tibia. No permita que el filtro se ensucie con tierra ni con pintura. La
exposición directa a condiciones de suciedad o áreas que se estén
pintando anulará la garantía.

WARNING:

AVERTISSEMENT:

ADVERTENCIA:

WARNING:

AVERTISSEMENT:

AVERTENCIA:

MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO

MAINTENANCE

DRAINING THE TANK

CLEANING THE AIR FILTER

ENTRETIEN

VIDANGE DU RÉSERVOIR

NETTOYAGE DU FILTRE À AIR

MANTENIMIENTO

DESAGÜE DEL TANQUE

LIMPIEZA DEL FILTRO DE AIRE

Summary of Contents for 200-2275

Page 1: ...ermate Compressors WILL NOT be liable for any damage because of failure to follow these instructions AVERTISSEMENT Lisez et veillez bien comprendre toutes les consignes de s curit de ce manuel avant d...

Page 2: ...structions de mise la terre 11 RODAGE DE LA POMPE 12 MODE D EMPLOI 13 Mise en marche quotidienne 13 Arr t 14 ENTRETIEN 15 Vidange du r servoir 15 Nettoyage du filtre air 15 V rification de la soupape...

Page 3: ...electrician in accordance with all local and national codes must install all wiring Never use an electric air compressor outdoors when it is raining or on a wet surface as it may cause an electric sho...

Page 4: ...s un compresseur d air lectrique l ext rieur quand il pleut ou sur une surface mouill e sous peine de vous exposer une d charge lectrique 4 RISQUE DE BLESSURE Cet appareil se met en marche automatique...

Page 5: ...erdo con todos los c digos el cricos nacionales y locales Nunca utilice un compresor el ctrico de aire en el exterior cuando est lloviendo ni lo coloque sobre una superficie mojada ya que esto podr a...

Page 6: ...prime l air Le r servoir C contient l air comprim Le manostat D arr te le moteur et lib re la pression d air dans la pompe et le tube de transfert quand la pression dans le r servoir atteint la pressi...

Page 7: ...ette de transport et d clarez les dommages aux transporteur Faites cette d marche imm diatement tant donn les d lais limites des demandes d indemnisation Le carton doit contenir compresseur d air poig...

Page 8: ...na distancia m nima de 12 pulgadas 31 cm de cualquier pared u obstrucci n en un rea limpia y bien ventilada para asegurar que exista suficiente flujo de aire y enfriamiento c En climas fr os almacene...

Page 9: ...rvoir L utilisateur ne peut pas r gler ce manom tre et il n indique pas la pression dans la conduite REMARQUE Seuls certains mod les sont munis des l ments suivants R gulateur de pression d air voir D...

Page 10: ...surface that is green with or without yellow stripes is the grounding wire This product is for use on a nominal 115 volt circuit A cord with a grounding plug as shown here shall be used Make sure that...

Page 11: ...mporizados de doble elemento s lo Buss Fusetron tipo T NOTA Evite el uso de cordones prolongadores Para obtener un rendimiento ptimo enchufe el cord n el ctrico del compresor directamente en un tomaco...

Page 12: ...tion ARR T 6 Fermez le robinet de purge D 7 Tourner le manocontacteur en position MARCHE Tourner vers la droite Le compresseur d marre et remplit le r servoir jusqu la pression de fermeture puis s arr...

Page 13: ...ecessary for your model so the petcock is at the bottom of the tank s Then open the petcock see B to allow moisture to drain from the tank 1 Placer le manocontacteur en position ARR T A 2 Fermez le ro...

Page 14: ...nto 4 Coloque el conmutador activado por presi n en la posici n ENCENDIDO vea C Al efectuar un ajuste desde una presi n m s alta a una m s baja gire la perilla a la izquierda hasta que sobrepase el aj...

Page 15: ...oute l humidit accumul e dans le r servoir Voir B et D aux pages 12 13 et 14 REMARQUE Dans les climats froids purger le r servoir apr s chaque utilisation afin de r duire les probl mes de gel d eau de...

Page 16: ...le compresseur pour une p riode prolong e utilisez une soufflette pour nettoyer toute la poussi re et tous les d bris du compresseur D branchez le cordon d alimentation et enroulez le Tirez sur la so...

Page 17: ...wing maintenance at the intervals indicated below Inspect and clean air filter Daily Operate the pressure relief valves Daily Drain tank Daily Realice el mantenimiento siguiente a los intervalos indic...

Page 18: ...r damaged regulator internal parts If pressure drops too low adjust regulator while accessory is used This is normal Check air requirement of accessory If it is higher than CFM and pressure supplied b...

Page 19: ...e Check for low voltage and proper extension cord size Disconnect other applications from circuit Operate compressor on a dedicated circuit Remove and clean or replace Check valve stuck open Bleed lin...

Page 20: ...uite de soupape Remplacer l ensemble piston et gaine de cylindre Fuite ou joint de piston us V rifier les raccords l eau savonneuse Resserrer ou tanch ifier les raccords NE PAS TROP SERRER Fuite des r...

Page 21: ...ou disjoncteur d clench V rifier le fusible le type T Fusetron est acceptable V rifier la faible tension et le calibre de la rallonge D brancher les autres appareils du circuit Faire fonctionner le c...

Page 22: ...ra de aire Reemplace inmediatamente el tanque NO intente repararlo Fugas en el tanque Reemplace todos los sellos defectuosos Sellos expulsados Reemplace las piezas desgastadas y vuelva a montar usando...

Page 23: ...ula de retenci n se bloque en posici n abierta Purgue la l nea moviendo la palanca del conmutador activado por presi n a la posici n APAGADO antes de volver a arrancar Si la v lvula de purga no se abr...

Page 24: ...Society of Mechanical Engineers Soci t am ricaine des ing nieurs m caniciens Indique que les composants sont fabriqu s test s et examin s selon les normes d finies par l ASME U L Underwriters Laborat...

Reviews: