18
Fittings /
Fastener
s
Check all fittings and
fasteners correct if
necessary.
z
Crankcase
breather
Check breather hose for
cracks or damage. Replace if
necessary
z
Generator Check the pilot light comes on
z
2
)
ENGINE OIL REPLACEMENT
1. Place the generator on a flat level surface and warm up the engine
for several minutes. Then stop the engine and turn the fuel cock
knob to the “
OFF
” position. Turn the fuel tank cap air vent knob
clockwise.
2. Loosen the screw and remove the cover.
3. Remove the oil filler cap
4. Place an oil pan under the engine and tilt the generator to drain the
oil completely.
5. Once the oil has drained return the generator to the upright position.
6. Add engine oil until it reaches the “upper level” indicator.
7. Replace the oil filler cap properly.
8. Replace the cover properly and tighten the screw.
z
Recommended
engine
oil:
(
see page 17
)
API Service “SJ”
CAUTION:
──────────────────────
z
Make sure that no foreign material falls into the crankcase.
z
Do not tilt the generator when adding engine oil as this could result in overfilling and could cause damage
to the engine
z
Make sure that you clean the oil filter every 100 hours.
───────────────────────────
3
)
AIR FILTER
Maintaining an air filter in proper condition is very important. Dirt that is
induced through improperly installed, improperly serviced, or inadequate
elements damages and wears out engines. Always keep the air filter
OIL FILTER
UPPER