Powerhouse PH1000i Operating Instructions Manual Download Page 36

 

36                                                                          PH1000i OM 2010-07-13

 

9. WARRANTY AND CONSUMER INFORMATION 

POWERHOUSE® GENERATOR WARRANTY 

Generators are covered by this warranty from the date of original retail purchase for a period of 2 years for 
residential use and 1 year for commercial applications. Units used in rental fleets, reconditioned or as 
demonstration models will be considered commercial usage. Batteries that are supplied with applicable products 
as standard, original equipment will be covered for a period of one year. The warranty coverage is continual from 
the original date of purchase, and does not restart upon the replacement of any part or complete unit. Individual 
parts replaced at any point during the warranty period are only eligible for warranty coverage for the balance of 
the original warranty period.   

Eligibility 

To be eligible for warranty replacement, the product must be purchased in the United States or Canada from an 
authorized Coast Distribution dealer. This warranty applies to the original retail purchaser only, and is not 
transferable. Proof of purchase and the serial number is required.   

Coverage 

Pre-approved parts and labor costs will be covered by POWERHOUSE® for any failure that is proven to be a 
failure in material or workmanship under normal use during the applicable warranty time period. This coverage is 
limited to parts, labor and ground shipping of repair parts. It is the responsibility of the end user to return the 
product to the nearest authorized repair center as directed by the warranty administration center. If in the event 
that the generator is deemed to be not repairable or the necessary repair would be economically unfeasible, the 
warranty department will authorize its prepaid return to the nearest Coast location and Coast will prepay the 
returned shipping to the dealer, repair center or consumer. Coast Distribution reserves the right to repair or 
replace any part or unit at its option. Coast Distribution may request defective parts to be returned. Anything 
replaced under warranty becomes the property of Coast Distribution.   

To Obtain Warranty Service 

Contact any authorized dealer or contact our national customer service center at:   

Phone: 1-877-544-4449 
Fax: 1-800-263-0280 
E-mail: www.powerhouse-products.com 

If contacting us by fax or e-mail, be sure to include a description of the problem as well as all return contact info 
such as address, phone number, fax number, e-mail, etc. Engine serial number and proof of purchase is required.   

Exclusions 

THIS WARRANTY DOES NOT EXTEND TO PARTS AFFECTED OR DAMAGED BY ACCIDENT AND/OR 
COLLISION, NORMAL WEAR, FUEL CONTAMINATION OR DEGRADATION, USE IN AN APPLICATION FOR 
WHICH THE PRODUCT WAS NOT DESIGNED OR ANY OTHER MISUSE, NEGLECT, INCORPORATION OR 
USE OF UNSUITABLE ATTACHMENTS OR PARTS, UNAUTHORIZED ALTERATION, OR ANY CAUSES 
OTHER THAN DEFECTS IN MATERIAL OR WORKMANSHIP OF THE PRODUCT. THIS WARRANTY DOES 
NOT EXTEND TO NORMAL MAINTENANCE ITEMS SUCH AS BELTS, HOSES, SPARK PLUGS, WHEELS AND 
FILTERS PAST THE FIRST SCHEDULED REPLACEMENT OR SERVICE INTERVAL FOR THESE ITEMS 
WHICHEVER COMES FIRST.   

Disclaimer of Consequential Damage and Limitation of Implied Warranties 

COAST DISTRIBUTION DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR USE OF THE PRODUCT, 
TRANSPORTATION, COMMERCIAL LOSS, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGE. 
ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN LIMITED WARRANTY.   

Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or 
limitation of incidental or consequential damages. Therefore, the above exclusions and limitations may not apply 
to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to 
state.  

Replacement Parts Availability 

To purchase replacement parts please refer to the www.powerhouse-products.com website   

Summary of Contents for PH1000i

Page 1: ...PH1000i OM 2010 04 05 PH1000i Digital Inverter Generator OPERATING INSTRUCTIONS PLEASE READ THIS MANUAL CAREFULLY BEFORE USING...

Page 2: ...les 2 Open the fuel valve 3 Starting the engine Turn the ignition switch to the ON position Pull the starter grip lightly until resistance is felt then pull briskly out 4 The green run light will illu...

Page 3: ...nsult an authorized Powerhouse dealer Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s manual before operating this ge...

Page 4: ...4 7 Low oil alarm system 20 4 9 Stopping the engine 21 5 MAINTENANCE 22 5 1 Emission control system 22 5 2 Maintenance Schedule 24 5 3 Changing oil 25 5 4 Air cleaner service 26 5 5 Spark plug mainten...

Page 5: ...e generator in an enclosed area Be sure to provide adequate ventilation The muffler becomes very hot during operation and remains hot for several minutes after stopping the engine Be careful not to to...

Page 6: ...the generator on a level surface If the generator is tilted fuel spillage may result Know how to stop the generator quickly and understand operation of all controls Never permit anyone to operate the...

Page 7: ...7 PH1000i OM 2010 07 13 2 COMPONENT IDENTIFICATION Maintenance Cover Choke Lever Exhaust Grill Starter Grip Fuel Lever Fuel Cap Cover Spark Plug Access Cover Control Panel...

Page 8: ...on Green Overload Light Low Oil Alarm Light Run Light 120V 20A Duplex Receptacle 120V 20A Circuit Breaker Engine Switch Economy Switch Grounding Terminal Battery Charge Receptacle 12V 5A Battery Charg...

Page 9: ...er can be found stamped on the engine block above oil dipstick It is visible when the maintenance panel is removed The bar code label is found in two locations 1 On the bottom of the generator 2 On th...

Page 10: ...Select the appropriate viscosity for the average temperature in your area Loosen the cover screw and remove the maintenance cover Remove the oil filler cap and wipe the dipstick with a clean rag Check...

Page 11: ...er source of combustion away from the generator during refueling Do not overfill the fuel tank there should be no fuel above the upper limit mark After refueling make sure the tank cap is closed prope...

Page 12: ...think contains ethanol replace it by a gasoline that you know has the proper blend 3 3 Check the air cleaner 1 Check the air cleaner element to be sure it is clean and in good condition 2 Loosen the c...

Page 13: ...he ignition switch to the ON position 3 Move the choke lever to the START position 4 Pull the starter grip until resistance is felt then pull the starter grip briskly toward the arrow as shown below D...

Page 14: ...ately 3 5 for each 1000 feet 305 m increase in altitude The affect of altitude on the horsepower will be greater than this if no carburetor modification is made Operation of the generator at an altitu...

Page 15: ...he an external g dby power to electrician an Improper co o back feed in mpany worke n utility power n the building enerator to a ter module m d aulty applianc eavy cable be ground sourc a building s n...

Page 16: ...ion cable is required make sure you use the proper size and length 16 Gauge Cords Any 16 gauge cord between 0 and 100 feet long will adequately handle tool and appliance loads up to 10 amps 14 Gauge C...

Page 17: ...e overload light red may shorten the service life of the generator Be sure that all appliances are in good working order before connecting them to the generator If an appliance begins to operate abnor...

Page 18: ...he overload condition Red light press the Green overload reset button or stop and restart the generator The Green indicator light should be illuminated within 10 seconds Before connecting or reconnect...

Page 19: ...ry Disconnect the cable first at the battery Before connecting charging cables to a battery that is installed in a vehicle disconnect the vehicle s ground battery cable Reconnect the vehicle s ground...

Page 20: ...itch Economy switch ON This position is recommended to minimize fuel consumption and noise while in operation Engine speed is kept at idle automatically when the electrical load is disconnected and re...

Page 21: ...tion will automatically stop the engine with or without a load However continually stopping the generator without disconnecting all loads can cause damage to the generator or appliances Continually st...

Page 22: ...nous gas The emission of fuel vapors is a source of pollution as well The POWERHOUSE generator engine utilizes a precise air fuel ratio and emission control system to reduce the emissions of carbon mo...

Page 23: ...ment parts and accessories have the responsibility to guarantee that their replacement products will not adversely affect emission performance Maintenance Maintain the generator according to the maint...

Page 24: ...77 F 25 C 95 hr 86 F 30 C 85 hr 95 F 35 C 70 hr 104 F 40 C Item Maintenance Procedure Regular Service period 1 Perform at every indicated month or operating hour interval whichever occurs first Each U...

Page 25: ...il filler cap 3 Install the oil drain pipe 4 Drain dirty oil into a container thoroughly 5 Refill with the recommended oil and check the oil level 6 Reinstall the maintenance cover and tighten the scr...

Page 26: ...e rapid engine wear may result 1 Loosen the panel screw and remove the side maintenance panel 2 Remove air filter retaining screw Remove the air cover and check the element Clean or replace the elemen...

Page 27: ...e spark plug must be properly gapped and free of deposits 1 Loosen the cover screw and remove the spark plug maintenance cover 2 Remove the spark plug cap 3 Clean any dirt from around the spark plug b...

Page 28: ...eading 9 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress its washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn...

Page 29: ...it to cool before proceeding The spark arrestor must be serviced every 100 hours to maintain its efficiency 1 Remove the four M6 screws and remove the muffler grill 2 Remove the two M4 screws holding...

Page 30: ...rature inside the vehicle could cause residual fuel to vaporize resulting in a possible explosion If you must transport the generator in a vehicle drain all fuel from the generator 6 1 Exercising the...

Page 31: ...asoline from the fuel tank turn the engine switch to the OFF position 4 Attach a hose to the drain fitting on the carburetor and place the other end of the hose into an approved gasoline container 5 T...

Page 32: ...rk 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder head to gr...

Page 33: ...to a Powerhouse service center Check the electrical appliance or equipment for any defects Take the generator to an authorized Powerhouse service center Replace the electrical appliance or equipment T...

Page 34: ...stroke vertical shaft air cooled OHV gasoline engine Displacement 53 cc Compression ratio 7 4 1 Engine speed 5500 RPM with economy switch off Ignition system Electronic Spark plug A7RTC Starting syst...

Page 35: ...Plug Gap 0 024 0 028 in 0 6 0 7 mm Valve Clearance Intake 0 0039 0 0008 in 0 10 0 02mm Valve Clearance Exhaust 0 0059 0 0008 in 0 15 0 02mm Dimensions Overall dimension L W H in mm 18 3 x 9 8 x 15 1 i...

Page 36: ...Coast Distribution reserves the right to repair or replace any part or unit at its option Coast Distribution may request defective parts to be returned Anything replaced under warranty becomes the pr...

Page 37: ...stem is warranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by Coast Distribution System Inc Owner s Warranty Responsibilities As th...

Page 38: ...or including the choke system and replaceable high altitude main jets Engine speed control system Economy Throttle Intake manifold Engine control module Evaporative Control System Fuel tank Fuel cap F...

Page 39: ...ap indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere 2 A carbon activated canister collects gasoline vapors from the fue...

Page 40: ...NG AN OUTPUT VOLTAGE SELECTOR SWITCH REFER TO THE CAR OWNER S MANUAL IN ORDER TO DETERMINE THE VOLTAGE OF THE BATTERY AND TO MAKE SURE THE OUTPUT VOLTAGE IS SET AT THE CORRECT VOLTAGE IF AN OUTPUT VOL...

Page 41: ...Y MAY CAUSE A BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY i CHECK POLARITY OF BATTERY POSTS A POSITIVE POS P BATTERY POST USUALLY HAS A LARGER DIAMETER THAN A NEGATIVE NEG N POST ii ATTAC...

Reviews: