4.5 Output and Overload Lights
1.
The output indicator light (Green) will remain illuminated during normal operating conditions.
2.
If the generator is overloaded (In excess of 1.0 KW), or if there is a short in the connected appliance,
the output indicator light (Green) will go out, the overload indicator light (Red) will turn on and current
to the connected appliance will be shut off.
3.
Remove all electrical loads from the generator and investigate the cause of the overload.
4.
To reset the overload condition (Red light), press the (Green) overload reset button or stop and
restart the generator. The (Green) indicator light should be illuminated within 10 seconds.
■
Before connecting or reconnecting an appliance to the generator, check that it is
in good order, and that its electrical rating does not exceed that of the generator.
■
When an electric motor is started, both the overload indicator light (Red) and the
output indicator light (green) may go on simultaneously. This is normal if the
overload indicator light (red) goes off after about four (4) seconds. If the overload
indicator light (Red) stays on, consult your generator dealer.
Overload
Light
(Red)
120V
~
20A
Duplex
Receptacle
Overload
Reset
Button
(Green)