Machine Component Identification
16
Liquid Crystal
Display (LCD) Screen
When the main switch is
in the “ON” position
, the LCD screen will display
maintenance tips only if the engine is not started or when the engine is running
normally. Press the operating key
M
to clear and reset. The maintenance symbol
located to the left of the fuel quantity symbol will not be displayed until the operating
key
M
is cleared and reset.
The following symbols will display across the LCD screen when a failure occurs.
Over voltage
occurs when the AC voltage is > greater than 133V and DC
voltage is > greater than 275V for more than 1 second.
Under voltage
occurs when the AC voltage is < less than 108V and DC
voltage is < less than 36V for more than 5 seconds.
Output over current
occurs when the amps are > greater than 1.2 the
rated amps.
Output short circuit
occurs when an abnormal problem is encountered
with electrical power. The short circuit protection happens within 4 seconds to
protect the generator and stop further damage.
Overheat
condition occurs when the internal temperature of the inverter is
higher than 285 degrees Fahrenheit (285°F). Check for adequate air flow and any
blockages.
(27) Fault code symbol