GB

with a total area of at least 450 cm² must be
provided. A minimum room size of 170 m³ is
compulsory.

The gas fan heater must never be used in
basements or in rooms below ground level.

The gas fan heater must not be used to heat
inhabitable rooms in residential buildings.
Usage in public buildings must comply with
the regulations in force in your country!

Do not use the gas fan heater in leisure
vehicles such as caravans, motor homes
and boats.

No persons are allowed to remain in the
room where the equipment is being used.

Do not use the gas fan heater in rooms in
which there is already a gas cylinder.

The gas fan heater must not be operated
near other heaters (minimum distance 1 m),
inflammable materials or explosive
materials.

The gas fan heater must be set up with the
following safety distances between its
housing and combustible materials or walls:
2 m at the air intake end, 3 m at the air
discharge end, 1 m at the sides, 1.50 m at
the top.

Do not move the gas fan heater when it is in
operation.

After the gas fan heater has been in use and
each time before you move it, close the
valve on the liquid gas cylinder.

Use only the gas types and the liquid gas
cylinders specified by the manufacturer.

The liquid gas cylinder must be changed in
a well ventilated area away from naked
flames (candles, cigarettes or other
equipment with a naked flame). The gas
cylinder valve must be closed for this
purpose.

Check that the seal on the pressure
regulator is fitted correctly and that it can
perform its function.

If there is a gas leak, do not use the gas fan
heater. If it is already in use, the gas supply
must be shut off and the gas fan heater must
be inspected and repaired before it can be
used again.

In the event of a leak, close the shut-off
valve on the gas cylinder immediately and
open the doors and windows.

If you smell gas, do not switch any lights on
or off, actuate no other electrical switches
and do not use a telephone or mobile phone
in the danger area.

If you smell gas, do not use a naked flame
(e.g. a lighter or match) and do not smoke.

Check the hose lines (gas hose) at least
once a month and every time you change
the liquid gas cylinder. If the hose lines show
signs of becoming brittle or any other
damage, you must replace them with new
hoses of the same length and quality.

The gas hose must be replaced within the
specified periods (see section 8.2).

Check that the seal on the cylinder valve is
in good condition and is actually fitted. Do
not use additional seals.

Liquid gas cylinders must be protected from
direct sunlight and must be stored only in an
upright position.

The gas fan heater may be used only with a
connected pressure regulator with the
maximum output pressure as set in the
factory and indicated on the rating plate.

Do not kink or twist the gas hose.

Install and ignite in strict 

adherence to

the instructions.

If the equipment cannot be left in a safe
condition to run unattended, switch it off.

This equipment is not designed to be used by
people (including children) with limited physical,
sensory or mental capacities or those with no
experience and/or knowledge unless they are
supervised by a person who is responsible for
their safety or they have received instructions
from such a person in how to use the equipment
safely.
Children must always be supervised in order to
ensure that they do not play with the equipment.

Anleitung_2330444_DK:_  10.06.2011  11:16 Uhr  Seite 7

Summary of Contents for 23.304.44

Page 1: ...eration and Safety Notes Original operating instructions GASVARMEAPPARAT PGH 17 A1 G GASVARMEAPPARAT Brugs og sikkerhedsanvisninger Original betjeningsvejledning Anleitung_2330444_DK _ 10 06 2011 11 1...

Page 2: ...liarise yourself with all functions of the device F r du l ser vend siden med billeder frem og bliv bekendt med alle apparatets funktioner GB Operation and Safety Notes Page 5 DK Brugs og sikkerhedsan...

Page 3: ...3 1 5 1 2 3 9 7 8 4 6 Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 3...

Page 4: ...4 3 4 M M 1 Y 1 Y 2 F 1 N 1 Q 1 L 1 Ev B 1 B 4 B 3 B 2 2 G F D K N E Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 4...

Page 5: ...ion diagram 11 11 Technical data 11 12 Disposal and recycling 11 12 13 Troubleshooting 13 14 Spare parts list 14 15 Spare parts drawing 15 16 Declaration of conformity 16 17 Guarantee certificate 17 T...

Page 6: ...or open flames Never immerse the gas fan heater in water danger of fatal accident Never use the gas fan heater with wet hands Never open the gas fan heater and touch live parts danger of fatal acciden...

Page 7: ...must be shut off and the gas fan heater must be inspected and repaired before it can be used again In the event of a leak close the shut off valve on the gas cylinder immediately and open the doors an...

Page 8: ...sory The gas fan heater must never be used in basements or in rooms below ground level This gas fan heater is not designed for household use The gas fan heater may be used only for its intended purpos...

Page 9: ...aked flames candles cigarettes other devices with a naked flame etc 2 Close the cylinder valve F 3 Undo the union nut D on the pressure regulator 4 Take the pressure regulator E off the cylinder 5 Scr...

Page 10: ...r to cool the gas fan heater 3 Press the ON OFF switch 5 to switch off the fan 4 Pull the power plug out of the socket outlet 5 Disconnect the pressure regulator from the gas cylinder 8 Cleaning maint...

Page 11: ...ement B2 Piezo ignition B3 Ignition electrode B4 Burner 11 Technical data Rated thermal load max Hi 17 kW Air throughput 500 m3 h Gas consumption G 30 1340 g h Equipment category I3B P Country of dest...

Page 12: ...rly disposed of if he no longer wants to keep the equipment The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recyclin...

Page 13: ...linder valve closed Safety valve in the equipment has still not released the gas Replace the gas cylinder Open the valve Try again to switch on see section 7 1 2 Gas input too high or flame too big Pr...

Page 14: ...itor 086 75 859 02 12 Thermal element 086 75 911 06 13 Ignition electrode 086 75 811 06 14 Ignition guard 086 75 850 04 15 Solenoid valve 086 70 441 01 17 Angle piece with nozzle 086 89 510 07 18 Gas...

Page 15: ...15 GB 15 Spare parts drawing Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 15...

Page 16: ...ektywy WE e H paskaidro du atbilst bu ES direkt vai un standartiem G apib dina atitikim EU reikalavimams ir prek s normoms Q declar urm toarea conformitate conform directivei UE i normelor pentru arti...

Page 17: ...e or external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device This applies in particular to rechargeable batteries for which we n...

Page 18: ...ng 24 10 Forbindelsesdiagram 24 11 Tekniske data 24 12 Bortskaffelse og genanvendelse 24 25 13 Oplysninger om fejlafhj lpning 26 14 Reservedelsliste 27 15 Reservedelstegning 28 16 Overensstemmelseserk...

Page 19: ...ikke vikles rundt om apparatet Undg at netledningen kommer i klemme eller tr kkes hen over skarpe kanter pas ogs p at den ikke l gges hen over varme kogeplader eller ben ild Neds nk aldrig apparatet...

Page 20: ...kke anvendes er gasvarmebl seren i funktion skal der lukkes for gastilf rslen Herefter skal gasvarmebl seren efterses og udbedres inden den tages i brug igen I tilf lde af ut thed skal gasflaskens sp...

Page 21: ...il opvarmning bygningst rring og afisning i godt ventilerede lokaler eller i det fri Godt ventilerede lokaler skal have ventilerings og udluftnings bninger p mindst 450 cm2 Lokalet skal have en st rre...

Page 22: ...str 17 Du skal her holde imod med en anden skruen gle af samme st rrelse p de dertil indrettede n gleflader p trykregulatoren for at undg at regulatoren drejer med eller at kraftoverf ringen bliver f...

Page 23: ...ventilatoren k re videre i mindst 1 min inden du fors ger t nding igen indtil gassen er bl st helt ud Bem rk Hvis t nding er vanskelig eller uregelm ssig er det vigtigt at luftgennemstr mningen kontr...

Page 24: ...flydende gas m ikke opbevares i huset under grundniveau lokaler under jordplanet eller p steder uden udluftning Gasflaskens ventiler skal v re forsynet med beskyttelsesh tter og lukkem trikker Gasflas...

Page 25: ...m ssig forsvarlig vis Recycling alternativ til tilbagesendelse Ejeren af el v rkt jet er med mindre denne tilbagesender maskinen forpligtet til at bortskaffe maskinen og dens dele if lge milj forskrif...

Page 26: ...lukket Sikkerhedsventil i apparatet har ikke frigivet gas endnu Udskift gasflaske bn ventil Nyt indkoblingsfors g se kapitel 7 1 2 For h j gasindstr mning for stor flamme Trykregulator defekt Udskift...

Page 27: ...eraturdetektor 086 75 859 02 12 Termoelement 086 75 911 06 13 T ndelektrode 086 75 811 06 14 T ndsikring 086 75 850 04 15 Magnetventil 086 70 441 01 17 Kn stykke med dyse 086 89 510 07 18 Gasventilkna...

Page 28: ...28 DK 15 Reservedelstegning Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 28...

Page 29: ...rektywy WE e H paskaidro du atbilst bu ES direkt vai un standartiem G apib dina atitikim EU reikalavimams ir prek s normoms Q declar urm toarea conformitate conform directivei UE i normelor pentru art...

Page 30: ...ikke er godkendt tilsides ttelse af vedligeholdelses og sikkerhedsforskrifter indtr ngen af fremmedlegemer i apparatet f eks sand sten eller st v brug af vold eller eksterne p virkninger udefra f eks...

Page 31: ...31 Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 31...

Page 32: ...32 Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 32...

Page 33: ...33 Anleitung_2330444_DK _ 10 06 2011 11 16 Uhr Seite 33...

Page 34: ...R IAN 66769 PGH 17 A1 Einhell Germany AG Wiesenweg 22 D 94405 Landau Isar Last Information Update Tilstand af information 06 2011 Ident No 23 304 44 062011 DK 0085 Anleitung_2330444_DK _ 10 06 2011 11...

Reviews: