5
Climate Control Simplex
Maintenance Schedule
Item
Action
needed
Operating Hours
Remarks
Daily
500
1500
2500
5000
10,000
15,000
20,000
Tank
Drain moisture
●
●
Drain tank daily
Inlet air fi lter
Inspect,
Replace
●
▲
Every 2500 hours
or less
Pump
fl ywheel
Clean
●
●
●
●
Compressor
fi ns
Clean
●
Every 2500 hours
or less
Oil change
Replace
▲
Every 1500 hours
Compression
rings
Replace
▲
Check oil
Inspect
●
V-belt
Inspect,
Replace
●
▲
▲
▲
▲
See Note 3
Pressure
switch
Confi rm
operation
●
●
Magnetic
starter
Inspect
●
●
Safety valve
Confi rm
operation
●
Every 2500 hours
or less
Pressure
gauge
Inspect
●
Every 2500 hours
or less
●
Inspect
▲
Replace
NOTES:
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition
are adverse, shorten the cycle time and do maintenance accordingly.
3. The tension of the V-belt should be adjusted during initial start up and inspected every 1,500 hours afterwards.
Proper belt tension for 3/4 to 3 HP units is 2-3 lbs. / 0.5 inch defl ection.
Model
HP
Oil Capacity
0 to High (liters)
Oil Range
Low to High (liters)
LPS007
0.75
0.44
0.12
LPS010A
1.0
0.44
0.12
LPS020A
1.5 / 2
0.44
0.12
LPS030A
3
0.70
0.20
LPS050A
5
1.03
0.35
LPS075A
7.5
1.70
0.45
LPS100A
10
1.70
0.45
Oil Capacity Chart