2
Climate Control Simplex
Operation
Factory calibrated snap-acting DPST pressure electric
switches provide automatic cut-in and cut-out. Overpressure
protection is provided by an ASME safety relief valve. Receiver
tanks have a condensate drain valve with an extension for
easy access. All mounting bases are slotted for V-belt tension
adjustment to aid in maintaining proper compressor and
motor alignment.
All units are run through the factory break-in and are tested
for air delivery, leakage and power consumption.
Units are shipped with a proper fi ll of compressor oil in the
crankcase and are furnished with an intake fi lter/silencer with
a replaceable cartridge. This fi lter/silencer combination is
designed to remove contaminates in the inlet air and provide
quieter operation.
LUBRICATION
Check lubricating oil level at gauge. Refi ll if necessary. See
Figure 1.
Change oil according to maintenance schedule. Before
draining oil, remove oil supply cap and loosen oil drain cap to
release trapped air. Use Mobil Rarus 427
®
or Mobil DTE heavy
oils.
NOTE:
All pump models operate turning clockwise opposite
the motor shaft / pump fl ywheel / belt guard side of the unit.
Improper rotation will cause oil to spray out of the breather
vent opening.
Dispose of oil in accordance
with state or local codes.
AUTO E-DRAIN ASSEMBLY
(See Figure 2)
NOTE:
The automatic E-drain is assembled to tank.
1. Plug E-drain into 115V power outlet supply.
2. Adjust times accordingly.
Installation
MOUNTED AND CONNECTED OPTIONS
Magnetic Motor Starter
An optional magnetic motor starter which has been selected
and wired for the intended input voltage is available for all
units. All starters are furnished with properly sized overload
heaters.
Refrigerated Air Dryer
A factory mounted model Hankinson HPR 5-10 Series
refrigerated air dryer with automatic condensate drain trap
assembly, bypass valve is available as an option on all 3/4
through 3 Hp Powerex Simplex air compressors. Piping for air
dryer is done at the factory. Wiring to power source must be
done in the fi eld using integral cord and plug which fi ts into
a standard 120 volt receptacle.
Automatic Tank Drain
Powerex air compressors are ordered with either a manual or
electric type automatic tank drain. This unit is furnished with
a manual drain attachment.
Vibration Dampening Pads
Waffl e type design vibration pads are provided as standard
equipment.
Performance Specifi cations
Base Model
Motor Rating
Compressor RPM
Compressor Capacity ACFM
HP
RPM
100% Runtime
50% Runtime
33% Runtime
AS-107
--
1725
980
2.1
1.07
0.71
AS-007
0.75
1725
980
2.1
1.07
0.71
AS-110
--
1725
1120
3.5
1.74
1.15
AS-010
1.00
1750
1120
3.5
1.74
1.15
AS-015
1.5
1760
860
4.6
2.3
1.5
AS-020
2.0
1755
1250
6.9
3.4
2.3
AS-030
3.0
1725
1050
10.3
5.2
3.4
NOTE:
0.75 HP pumps must be used under altitudes of 5000 feet.
Above 5000 feet, 1 HP pumps must be used.