11
4111-0008 — April 2017
June 2017
Maintenance props in lowered location during installation and service.
1. Remove any control panel, bumpers or pelletizing
that may be banded to the dock leveler. Do not
remove banding on hoist cylinder or storage prop
at this time.
2. Make sure the mounting hardware of lifting
bracket(s) (A) is tight but allows the bracket(s) to
pivot relatively freely on the mounting cap screw.
DO NOT over tighten.
3. Attach lifting chain to lifting bracket(s) (A) and to
a lifting device (i.e., hoist or fork truck) having the
appropriate lifting capacity and reach.
NOTE: Overall length of lifting chain and bracket
(A) must be kept to a minimum to prevent
interference between the lifting equipment
and the building ceiling or door as the dock
leveler is lowered into the pit.
INSTALLATION
Installation of VS levelers from inside is
recommended due to combined height of leveler
and proper lifting equipment may be greater than
outside door height.
A
Summary of Contents for VS series
Page 44: ...42 4111 0008 April 2017 June 2017 Centra Power Hydraulic Components PARTS A B E D F G I H C ...
Page 47: ...45 4111 0008 April 2017 June 2017 This page was left intentional left blank PARTS ...