34
4111-0034 — Sept. 2018
© 2018 Systems, LLC
A— Lip Latch Spring
Adjustment
B— Lip Actuator Spring
Adjustment
Adjust Lip Latch & Lip Actuator Spring Tension
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete.
A hard hat or other applicable head protection
should always be worn when working under or
around a dock leveler.
Always stand clear of platform lip when working in
front of the dock leveler.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
In addition, it is recommended and good safety
practice to use an additional means to support
the dock platform and lip anytime when physically
working in front of or under the dock leveler. This
additional means may include, but is not limited to a
boom truck, fork truck, stabilizing bar or equivalent.
ADJUSTMENTS
Figure 26
B
A
Summary of Contents for CentraAir