When the fuel has drained from the tank, close the fuel valve
and reinstall fuel line securely on petcock.
DRAINING THE CARBURETOR
Turn the engine switch
OFF
( O )
.
Turn the fuel valve to the
OFF
position.
Position a suitable container under the carburetor drain screw
to catch fuel; loosen the screw.
Allow fuel to drain completely into container.
Retighten drain screw.
NOTE
: Consult hazardous waste management guidelines in
your area for the proper way to dispose of used fuel.
TRANSPORTING
Turn the engine switch
OFF ( O )
. Disconnect any equipment
that is plugged into the generator.
Turn the fuel valve to the
OFF
position.
Allow 30 minutes of “cool down” time before storing the
machine.
For security, insert the pins to secure the handles before
transporting.
Tilt the machine away from you until it balances on the
wheels, then roll the machine to the desired location.
REPLACING FUEL FILTER
See Figure 21.
Occasionally the fuel filter may become clogged and need replac-
ing. To purchase a replacement fuel filter contact Powerstroke
customer service at 1-877-617-3501.
NOTE:
Fuel tank must be empty before replacing fuel filter. Run
unit until tank is empty, if needed, or inspect filter prior to fill-up.
To replace:
Turn the fuel valve to the
OFF
position.
Remove the fuel line from both sides of the filter by squeez-
ing the ends of the retaining clip with pliers.
Slide the fuel line off.
Replace with new fuel filter.
Reinstall fuel lines to new fuel filter.
Turn the fuel valve to the
ON
position.
CHANGING ENGINE BATTERY CHARGE
CIRCUIT FUSE
See Figure 22.
NOTICE:
Do not use a higher rated fuse other than the specified am-
perage. This could cause damage to the product.
Grip both sides of the plastic fuse holder and twist apart to
reveal the fuse and spring.
Insert new fuse and refasten the fuse holder by pushing the
two sides of the connector together and twisting to secure.
NOTE:
If spring came out of fuse holder when it was opened,
it should also be replaced inside the fuse holder before se-
curing.
USING THE BATTERY MAINTAINER
See Figure 23.
When storing the generator, the battery maintainer can be
connected to keep the battery fully charged and ready for use.
NOTE:
The battery maintainer provided should only be used
with the 12V 18Ah/20HR lead acid battery model FM12180
supplied with this generator.
Connect the battery maintainer to the power supply. Make
sure the power supply is normal household voltage, 120
volts, AC only, 60 Hz.
Attach the other end of the battery maintainer to the charg-
ing cable attached to the battery. The red light on the plug
will illuminate to show the battery is charging. The battery
will become slightly warm to the touch while charging. This
is normal and does not indicate a problem. When battery is
fully charged, the red light will turn green.
NOTE:
If the light does not illuminate, the fuse on the charging
cable may need to be replaced. Check the fuse and replace
if needed.
Disconnect the battery maintainer before operating the
generator. Place the cover on the charging cable when not
in use.
BATTERY REMOVAL AND PREPARATION
FOR RECYCLING
To preserve natural resources, please recycle
or dispose of batteries properly.
This product uses lead acid batteries. Local,
state or federal laws may prohibit disposal of
batteries in ordinary trash.
Consult your local waste authority for information regarding
available recycling and/or disposal options.
WARNING:
Upon removal, cover the battery’s terminals with heavy-duty
adhesive tape. Do not attempt to destroy or disassemble
battery or remove any of its components. Lead acid batter-
ies must be recycled or disposed of properly. Also, never
touch both terminals with metal objects and/or body parts
as short circuit may result. Keep away from children. Failure
to comply with these warnings could result in fire and/or
serious injury.