background image

Page 18  — English

SPARK PLUG MAINTENANCE

See Figure 17.

The spark plug must be properly gapped and free of deposits 
in order to ensure proper engine operation. To check:

 

Remove the spark plug cap.

 

Clean any dirt from around base of spark plug.

 

Remove spark plug using wrench (not included).

 

Inspect spark plug for damage, and clean with a wire 
brush before reinstalling. If insulator is cracked or  
chipped, spark plug should be replaced. For replacement 
spark plug, see 

Product Specifications 

earlier in this manual 

or the accompanying engine manual, if applicable.

 

Measure  plug  gap.  The  correct  gap  is  0.028−0.031  in. 

 

(0.7-0.8 mm). To widen gap, if necessary, carefully bend the 
ground (top) electrode. To lessen gap, gently tap ground 
electrode on a hard surface.

 

Seat spark plug in position; thread in by hand to prevent 
cross-threading.

 

Tighten with wrench to compress washer. If spark plug is 
new, use 1/2 turn to compress washer appropriate amount. If 
reusing old spark plug, use 1/8 to 1/4 turn for proper washer 
compression. 

 

NOTE

:  An improperly tightened spark plug will become very 

hot and could damage the engine.

 

Reinstall the spark plug cap.

CLEANING THE EXHAUST PORT AND 
MUFFLER

Depending on the type of fuel used, the type and amount of 
lubricant used, and/or your operating conditions, the exhaust 
port and muffler may become blocked with carbon deposits. If 
you notice a power loss with your gas-powered products, you 
may need to remove these deposits to restore performance. 
We highly recommend that only qualified service technicians 
perform this service.

SPARK ARRESTOR

See Figure 18.

NOTICE:

This product is equipped with a spark arrestor that has been 
evaluated by the USDA Forest Service; however, product 
users must comply with Federal, State, and local fire preven-
tion regulations. Check with appropriate authorities. Contact 
customer service or a qualified service center to purchase 
a replacement spark arrestor.

 

Inspect the spark arrestor for breaks or holes. Clean or replace 
if necessary. 

 

Use a brush (not provided) to remove carbon deposits from 
the spark arrestor screen as needed.

DRAINING FUEL TANK

See Figures 19 - 20.

To help prevent gum deposits in the fuel system, drain the fuel 
from the tank before storing.

 

Turn the engine switch 

OFF  ( O ).

 

Turn the fuel valve to the 

OFF

 

(O )

 position.

 

Remove the fuel line from the hose barb by squeezing the 
end of the retaining clip and sliding the fuel line off.

 

NOTE:

 Make sure you are removing the fuel line that runs 

between the fuel valve and the fuel filter, 

NOT

 the line that 

runs between the fuel valve and the fuel tank.

 

Place the fuel line with fuel valve in a fuel container large 
enough to catch the fuel being drained from the tank.

 

Turn the fuel valve to the 

ON  ( l )

 position.

 

When the fuel has drained from the tank, close the fuel valve 
and reinstall fuel line securely on hose barb.

REPLACING FUEL FILTER

See Figure 21.

Occasionally the fuel filter may become clogged and need to be 
replaced. To purchase a replacement fuel filter, contact customer 
service or a qualified service center.

NOTE: 

Fuel tank must be empty before replacing fuel filter. Run 

unit until tank is empty, if needed, or inspect filter prior to fill-up.

To replace:

 

Turn the fuel valve to the 

OFF

 

( O ) 

position.

 

Drain the fuel tank completely.

 

Remove both fuel lines from the old fuel filter by squeezing 
the ends of the retaining clips and sliding the fuel lines off.

 

Reinstall fuel lines to the new fuel filter.

 

Pull on lines to make sure they are secured

 

Turn the fuel valve to the 

ON

 

( I ) 

position.

TRANSPORTING

 

Turn the engine switch 

OFF  ( O )

.

 

Disconnect any equipment that is plugged into the generator.

 

Verify the fuel valve is in the 

OFF

 

( O ) 

position.

  Allow 30 minutes of “cool down” time before storing the 

machine. Make sure engine and exhaust of unit are cool.

 

For security, insert the pins to secure the handles before 
transporting.

  Tilt the machine toward you until it balances on the wheels, 

then roll the machine to the desired location.

 

If transporting in a vehicle, drain the fuel tank, close fuel valve, 
and securely restrain the generator.

 

Provide a plastic sheet or absorbent pad below the generator 
to catch any drips of fuel or lubricant.

MAINTENANCE

Summary of Contents for PS906522MFI

Page 1: ...ketools com SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product ADVERTENCIA Para reducir el rie...

Page 2: ...cept culos I Fuel valve v lvula de combustible J Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite K Oil drain plug tap n de drenaje del aceite L Engine switch interruptor del moto...

Page 3: ...ig 8 Fig 7 A C Fig 5 Fig 3 10 9 1 2 3 4 6 11 5 8 7 A C B D B E D C A A Handle mango B Handle lock pin pasador de seguro del mango C Handle release knob perilla de liberaci n del mango A C B A Oil cap...

Page 4: ...del filtro de aire A D B C A Oil drain plug tap n de drenaje del aceite B Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite B A A Engine switch in ON position interruptor del motor...

Page 5: ...filter filtro de combustible A A Fuel valve v lvula de combustible B Hose barb conector de manguera dentada C Fuel line conducto de combustible B C A Fuse holder sujetador de la fusible B Fuse fusible...

Page 6: ...rely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code contains several practical ways in which to establish a good ground source I...

Page 7: ...ical codes Do not allow children or untrained individuals to use this unit Do not start or operate the engine in a confined space building near open windows or in other unventilated space where danger...

Page 8: ...nder during or immediately after use they are HOT and will cause burn injury Do not allow the generator s gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allo...

Page 9: ...It will only activate due to the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas The carbon monoxide shutoff feature on this generator is not a substitu...

Page 10: ...th Hot Surface and Exhaust Gases To reduce the risk of injury or damage avoid contact with any hot surface and do not place any body parts in the path of hot exhaust gases Lifting Hazard To reduce the...

Page 11: ...well ventilated outdoor areas away from open windows or doors Do not expose to rain or use in damp locations Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxi...

Page 12: ...does not include a ground rod or copper wire Call a qualified electrician for local grounding requirements SPARK ARRESTOR Operation of this equipment may create sparks that can start fires around dry...

Page 13: ...1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 NOTICE Operating voltage and frequency requirement of all electronic equipment should be checked p...

Page 14: ...e generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as...

Page 15: ...Dindicatorlightinthecontrolpanelwillilluminatetoindicate afaultintheengine sfuelinjectionsystem Pleasecontactcustomer service or a qualified service center for assistance DIGITAL DISPLAY The digital d...

Page 16: ...not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to...

Page 17: ...wires to the positive terminal first then connect the black wire to the negative terminal Make sure all connections are tight NOTE Be careful not to short across the terminals when installing Shortin...

Page 18: ...or assistance APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT Only use OUTSID...

Page 19: ...ant after the initial 25 hours of run time When a cumulative time of 50 hours is reached P50 will display on the meter to remind you to clean the air filter When a cumulative time of 100 hours is reac...

Page 20: ...the START position Release the switch when the engine starts NOTE The battery may require charging before the gen erator can be started using the engine switch Once the generator is started the batter...

Page 21: ...etc Do not use a garden hose to clean the generator Water enter ing the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator To clean the uni...

Page 22: ...sh not provided to remove carbon deposits from the spark arrestor screen as needed DRAINING FUEL TANK See Figures 19 20 To help prevent gum deposits in the fuel system drain the fuel from the tank bef...

Page 23: ...able when not in use BATTERY REMOVAL AND PREPARATION FOR RECYCLING To preserve natural resources please recycle or dispose of batteries properly Thisproductusesleadacidbatteries Local state or federal...

Page 24: ...Spark Plug Replace Spark Plug2 Check Clean Spark Screen Check Adjust Idle Speed Check Adjust Valve Clearance1 2 Check Adjust Head Bolt Torque1 2 Fuel Filter Inspect Replace 1 These items should only...

Page 25: ...gasoline or refueled with bad gasoline Check air filter element Clean or replace as needed Contact a qualified service center Drainfuel Refuelwithfreshgasoline Ifproblem continues contact a qualified...

Page 26: ...Page 22 English NOTES NOTAS...

Page 27: ...ocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo superior de la jabalina debe estar al ras del suelo o por debajo del rasante o protegi...

Page 28: ...s bater as No conecte la unidad al sistema el ctrico de un edificio a menos que el generador y el interruptor de transferencia se hayan instalado correctamente y que un electricista calificado haya ve...

Page 29: ...e usarla para ver si tiene tornillos flojos fugas de combustible etc Reemplace toda pieza da ada PELIGRO Riesgo de incendios y lesiones por quemaduras Nunca retire la tapa de combustible mientras est...

Page 30: ...esultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido Para usarse s lo en el exterior NUNCA ignore un evento de apagado autom tico SI SE PRODUCE...

Page 31: ...io debe leer y comprender el manual del operador antes de usar este producto Alerta de condiciones h medas No exponga la unidad a la lluvia ni la use en lugares h medos Descarga el ctrica Si no se usa...

Page 32: ...UERTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POC...

Page 33: ...o incluye un cable de cobre ni una jabalina de puesta a tierra Consulte con un electricista calificado para conocer los requisitos locales de puesta a tierra PARACHISPAS El uso de este equipo puede pr...

Page 34: ...75 N A 850 1200 1 6 275 600 850 2050 1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 AVISO El requerimiento de voltaje y frecuencia operativa de to...

Page 35: ...ado al agregar cargas el ctricasalgenerador NOdebehaberequipoalgunoconectado a los tomacorrientes del generador antes de poner en marcha el motor respectivo La manera correcta y segura de administrar...

Page 36: ...n un centro de servicio calificado para recibir asistencia PANTALLA DIGITAL La pantalla digital muestra el voltaje de CA de salida la frecuencia cu nto tiempo hace que el motor est en marcha desde la...

Page 37: ...r ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cualquier alteraci n o modificaci n constituye maltrato y puede causar una condici n peligrosa y...

Page 38: ...onecte el cables rojo con la terminal positiva y el cable negro con la terminal negativa Aseg rese de que todas las conexiones est n firmes NOTA Teniendo cuidado de no causar cortocircuito en las term...

Page 39: ...adas faltantes o sueltas como tornillos tuercas pernos tapas etc Apriete firmemente todos los sujetadores y las tapas y no accione este producto hasta que todas las partes faltantes o da adas sean re...

Page 40: ...s ruedas VERIFICACI N Y ABASTECIMIENTO DE LUBRICANTE Vea la figura 9 AVISO Si se intenta arrancar el motor antes de haberse abastecido debidamente de lubricante podr a descomponerse el equipo NOTA Sir...

Page 41: ...de arranque tanto de impacto trasero como el ctrico Evite el uso prolongado de arranque con manivela pues esto puede da ar el motor La bater a que se suministra es de plomo cido de 12 voltios nominale...

Page 42: ...el cable de la buj a y al jelo de sta Permita un per odo de enfriamiento de 30 minutos antes de efectuar cualquier tarea de mantenimiento El incumplimiento de cualquiera de estas instrucciones puede...

Page 43: ...ado debe desecharse en un sitio de desecho aprobado Si necesita m s informaci n consulte a un concesionario de aceite de la localidad MANTENIMIENTO DE LA BUJ A Vea la figura 17 Labuj adebetenereldebid...

Page 44: ...on el servicio al cliente o con un centro de servicio calificado NOTA El tanque de combustible debe estar vac o antes de reemplazarelfiltro Siesnecesario pongaenfuncionamiento la unidad hasta vaciar e...

Page 45: ...o de bater a de plomo y cido RT12150 de 12V 15AH 20 HR horas provista con este generador Conecte el mantenedor de carga de la bater a a la l nea de alimentaci n Aseg rese de que el suministro de corri...

Page 46: ...r limpiar pantalla parachispas Verificar ajustar r gimen de ralent Verificar ajustar holguera de la v lvula1 2 Verificar ajustar par de torsi n del perno con cabeza1 2 Filtro de combustible Inspec cio...

Page 47: ...o de gasolina o reabastecido de gasolina de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Comun quese con un centro de servicio calificado Vac e el combus...

Page 48: ..._ MANUFACTURING NO ___________________________________________ SERIAL NO ______________________________________________________ SERVICIO Para obtener piezas o servicio comun quese con el centro de ser...

Reviews: