background image

Page 14  — English

 WARNING:

NEVER ignore an automatic shutoff event. IF AUTOMATIC 
SHUTOFF OCCURS – YOU MUST leave the area imme-
diately and relocate to an open outdoor area. Ventilate 
the area thoroughly before occupying again. Ensure the 
generator is located in an open, outdoor area. Always 
point exhaust away from occupied structures. Never 
run the generator in enclosed areas (e.g. not in a house 
or garage). Failure to follow these instructions can lead 
to carbon monoxide (CO) poisoning which can result in 
death or serious personal injury.

WARNING: 

If this generator will be used 

only

 with cord and plug-

connected equipment, National Electric Code does not 
require that the unit be grounded. However, other methods 
of using the generator may require grounding to reduce the 
risk of shock or electrocution. Consult a qualified electrician, 
electrical inspector, or local agency having jurisdiction for 
local codes or ordinances to find out if grounding is needed 
in your situation before using the generator.  

WARNING

Do not allow familiarity with this product to make you 
careless. Remember that a careless fraction of a second 
is sufficient to inflict serious injury.

WARNING

:

Do not use any attachments or accessories not 
recommended by the manufacturer of this product. The 
use of attachments or accessories not recommended 
can result in serious personal injury.

NOTICE:

This product is equipped with a spark arrestor that has 
been evaluated by the USDA Forest Service; however, 
product users must comply with Federal, State, and local 
fire prevention regulations. Check with appropriate au-
thorities. Contact customer service or a qualified service 
center to purchase a replacement spark arrestor.

NOTICE:

Before each use, inspect the entire product for damaged, 
missing, or loose parts such as screws, nuts, bolts, 
caps, etc. Tighten securely all fasteners and caps and 
do not operate this product until all missing or damaged 
parts are replaced. Please contact customer service or 
a qualified service center for assistance.

APPLICATIONS

This generator is designed to supply electrical power for 
operating compatible electrical lighting, appliances, tools, 
and motor loads.

BEFORE OPERATING THE UNIT

 

Only use OUTSIDE and at least 20 feet away from win-
dows, doors, and vents as recommended by the U.S 
Department of Health and Human Services Centers for 
Disease Control and Prevention. Your specific home and/ 
or wind conditions may require additional distance. 

 

NEVER use inside a home or garage, EVEN IF doors and 
windows are open.

 

Always position the generator on a flat firm surface.

SPECIAL REQUIREMENTS:

There may be General or State Occupational Safety and 
Health Administration (OSHA) regulations, local codes or 
ordinances that apply to the intended use of the generator.  
Please consult a qualified electrician, electrical inspector, or 
the local agency having jurisdiction:

 

In some areas, generators are required to be registered 
with local utility companies.

 

If the generator is used at a construction site, there may 
be additional regulations which must be observed.

RAISING AND LOWERING THE HANDLE

See Figure 8.

 

To raise the handle (for moving the generator): pull the 
handle release knob out, raise the handle, then release 
the knob so it snaps into the locking position. Insert the 
handle lock pin to secure the handle in place. 

 

To lower the handle (for storing or transporting the 
 generator): remove the handle lock pin, then pull the 
handle release knob out and lower the handle to the down 
position.

Never use the handle to lift the generator. The handle should 
only be used for moving the unit by rolling it on its wheels.

CHECKING/ADDING LUBRICANT

See Figure 9.

NOTICE:

Attempting to start the engine before it has been properly 
filled with lubricant will result in equipment failure.

NOTE: If a separate engine manual is provided for this 
product, please follow the instructions provided in the 
engine manual instead of the information listed below. 

Engine lubricant has a major influence on engine perfor-
mance and service life. For general, all-temperature use, 
SAE 10W-30 is recommended. Always use a 4-stroke motor 
lubricant that meets or exceeds the requirements for API 
service classification SJ.

OPERATION

Summary of Contents for PS906522MFI

Page 1: ...ketools com SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product ADVERTENCIA Para reducir el rie...

Page 2: ...cept culos I Fuel valve v lvula de combustible J Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite K Oil drain plug tap n de drenaje del aceite L Engine switch interruptor del moto...

Page 3: ...ig 8 Fig 7 A C Fig 5 Fig 3 10 9 1 2 3 4 6 11 5 8 7 A C B D B E D C A A Handle mango B Handle lock pin pasador de seguro del mango C Handle release knob perilla de liberaci n del mango A C B A Oil cap...

Page 4: ...del filtro de aire A D B C A Oil drain plug tap n de drenaje del aceite B Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite B A A Engine switch in ON position interruptor del motor...

Page 5: ...filter filtro de combustible A A Fuel valve v lvula de combustible B Hose barb conector de manguera dentada C Fuel line conducto de combustible B C A Fuse holder sujetador de la fusible B Fuse fusible...

Page 6: ...rely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code contains several practical ways in which to establish a good ground source I...

Page 7: ...ical codes Do not allow children or untrained individuals to use this unit Do not start or operate the engine in a confined space building near open windows or in other unventilated space where danger...

Page 8: ...nder during or immediately after use they are HOT and will cause burn injury Do not allow the generator s gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allo...

Page 9: ...It will only activate due to the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas The carbon monoxide shutoff feature on this generator is not a substitu...

Page 10: ...th Hot Surface and Exhaust Gases To reduce the risk of injury or damage avoid contact with any hot surface and do not place any body parts in the path of hot exhaust gases Lifting Hazard To reduce the...

Page 11: ...well ventilated outdoor areas away from open windows or doors Do not expose to rain or use in damp locations Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxi...

Page 12: ...does not include a ground rod or copper wire Call a qualified electrician for local grounding requirements SPARK ARRESTOR Operation of this equipment may create sparks that can start fires around dry...

Page 13: ...1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 NOTICE Operating voltage and frequency requirement of all electronic equipment should be checked p...

Page 14: ...e generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as...

Page 15: ...Dindicatorlightinthecontrolpanelwillilluminatetoindicate afaultintheengine sfuelinjectionsystem Pleasecontactcustomer service or a qualified service center for assistance DIGITAL DISPLAY The digital d...

Page 16: ...not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to...

Page 17: ...wires to the positive terminal first then connect the black wire to the negative terminal Make sure all connections are tight NOTE Be careful not to short across the terminals when installing Shortin...

Page 18: ...or assistance APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT Only use OUTSID...

Page 19: ...ant after the initial 25 hours of run time When a cumulative time of 50 hours is reached P50 will display on the meter to remind you to clean the air filter When a cumulative time of 100 hours is reac...

Page 20: ...the START position Release the switch when the engine starts NOTE The battery may require charging before the gen erator can be started using the engine switch Once the generator is started the batter...

Page 21: ...etc Do not use a garden hose to clean the generator Water enter ing the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator To clean the uni...

Page 22: ...sh not provided to remove carbon deposits from the spark arrestor screen as needed DRAINING FUEL TANK See Figures 19 20 To help prevent gum deposits in the fuel system drain the fuel from the tank bef...

Page 23: ...able when not in use BATTERY REMOVAL AND PREPARATION FOR RECYCLING To preserve natural resources please recycle or dispose of batteries properly Thisproductusesleadacidbatteries Local state or federal...

Page 24: ...Spark Plug Replace Spark Plug2 Check Clean Spark Screen Check Adjust Idle Speed Check Adjust Valve Clearance1 2 Check Adjust Head Bolt Torque1 2 Fuel Filter Inspect Replace 1 These items should only...

Page 25: ...gasoline or refueled with bad gasoline Check air filter element Clean or replace as needed Contact a qualified service center Drainfuel Refuelwithfreshgasoline Ifproblem continues contact a qualified...

Page 26: ...Page 22 English NOTES NOTAS...

Page 27: ...ocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo superior de la jabalina debe estar al ras del suelo o por debajo del rasante o protegi...

Page 28: ...s bater as No conecte la unidad al sistema el ctrico de un edificio a menos que el generador y el interruptor de transferencia se hayan instalado correctamente y que un electricista calificado haya ve...

Page 29: ...e usarla para ver si tiene tornillos flojos fugas de combustible etc Reemplace toda pieza da ada PELIGRO Riesgo de incendios y lesiones por quemaduras Nunca retire la tapa de combustible mientras est...

Page 30: ...esultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido Para usarse s lo en el exterior NUNCA ignore un evento de apagado autom tico SI SE PRODUCE...

Page 31: ...io debe leer y comprender el manual del operador antes de usar este producto Alerta de condiciones h medas No exponga la unidad a la lluvia ni la use en lugares h medos Descarga el ctrica Si no se usa...

Page 32: ...UERTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POC...

Page 33: ...o incluye un cable de cobre ni una jabalina de puesta a tierra Consulte con un electricista calificado para conocer los requisitos locales de puesta a tierra PARACHISPAS El uso de este equipo puede pr...

Page 34: ...75 N A 850 1200 1 6 275 600 850 2050 1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 AVISO El requerimiento de voltaje y frecuencia operativa de to...

Page 35: ...ado al agregar cargas el ctricasalgenerador NOdebehaberequipoalgunoconectado a los tomacorrientes del generador antes de poner en marcha el motor respectivo La manera correcta y segura de administrar...

Page 36: ...n un centro de servicio calificado para recibir asistencia PANTALLA DIGITAL La pantalla digital muestra el voltaje de CA de salida la frecuencia cu nto tiempo hace que el motor est en marcha desde la...

Page 37: ...r ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cualquier alteraci n o modificaci n constituye maltrato y puede causar una condici n peligrosa y...

Page 38: ...onecte el cables rojo con la terminal positiva y el cable negro con la terminal negativa Aseg rese de que todas las conexiones est n firmes NOTA Teniendo cuidado de no causar cortocircuito en las term...

Page 39: ...adas faltantes o sueltas como tornillos tuercas pernos tapas etc Apriete firmemente todos los sujetadores y las tapas y no accione este producto hasta que todas las partes faltantes o da adas sean re...

Page 40: ...s ruedas VERIFICACI N Y ABASTECIMIENTO DE LUBRICANTE Vea la figura 9 AVISO Si se intenta arrancar el motor antes de haberse abastecido debidamente de lubricante podr a descomponerse el equipo NOTA Sir...

Page 41: ...de arranque tanto de impacto trasero como el ctrico Evite el uso prolongado de arranque con manivela pues esto puede da ar el motor La bater a que se suministra es de plomo cido de 12 voltios nominale...

Page 42: ...el cable de la buj a y al jelo de sta Permita un per odo de enfriamiento de 30 minutos antes de efectuar cualquier tarea de mantenimiento El incumplimiento de cualquiera de estas instrucciones puede...

Page 43: ...ado debe desecharse en un sitio de desecho aprobado Si necesita m s informaci n consulte a un concesionario de aceite de la localidad MANTENIMIENTO DE LA BUJ A Vea la figura 17 Labuj adebetenereldebid...

Page 44: ...on el servicio al cliente o con un centro de servicio calificado NOTA El tanque de combustible debe estar vac o antes de reemplazarelfiltro Siesnecesario pongaenfuncionamiento la unidad hasta vaciar e...

Page 45: ...o de bater a de plomo y cido RT12150 de 12V 15AH 20 HR horas provista con este generador Conecte el mantenedor de carga de la bater a a la l nea de alimentaci n Aseg rese de que el suministro de corri...

Page 46: ...r limpiar pantalla parachispas Verificar ajustar r gimen de ralent Verificar ajustar holguera de la v lvula1 2 Verificar ajustar par de torsi n del perno con cabeza1 2 Filtro de combustible Inspec cio...

Page 47: ...o de gasolina o reabastecido de gasolina de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Comun quese con un centro de servicio calificado Vac e el combus...

Page 48: ..._ MANUFACTURING NO ___________________________________________ SERIAL NO ______________________________________________________ SERVICIO Para obtener piezas o servicio comun quese con el centro de ser...

Reviews: